Everwarm CHF-100 Скачать руководство пользователя страница 1

GENERAL

INSTAL

GUIDE

LATION

www.

EverWarm

.

net

Содержание CHF-100

Страница 1: ...GENERAL INSTAL GUIDE LATION www EverWarm net...

Страница 2: ...0 120 CHK 50 240 CHF 100 CHK 100 120 CHK 100 240 CHF 200 CHK 200 240 CHF 550 THE DOCUMENTATION PROVIDED HEREIN PERTAINS SOLEY TO THE USE AND INSTALLATION OF EverWarm Radiant Heat FILM EverWarm RADIANT...

Страница 3: ...21 23 SECTION 5 GENERAL INSTALLATION INSTRUCTIONS 24 32 LAYOUT 24 INSTALLING HEATING FILM 26 ATTACHING HARNESS 27 TESTING CONNECTIONS AND HEATING FILM MEASURING OHM S 28 OHM S READINESS TEST 29 APPLY...

Страница 4: ...rior to energizing the product for the first time All components must be recognized and rated for their use NEVER OVERLAP LAYER OR STACK THE HEATING FILM ON TOP OF ANOTHER PIECE OF THE HEATING FILM Th...

Страница 5: ...r stack the Heating Film on top of another piece of the Heating Film 6 DO NOT install the Heating Film over pre existing linoleum PVC or vinyl floor coverings All must be removed including all pre exi...

Страница 6: ...C Minimum installation temperature 50 F 10 C SKILL REQUIREMENTS Installation must be performed by qualified persons in accordance with local codes ANSI NFPA 70 NEC Article 424 and CEC Part 1 Section...

Страница 7: ...own the length of the Heating Film 2 bus bars are required to create heat see drawing Should a copper bus bar be cut during the installation of the product you may repair it by either adding an Adder...

Страница 8: ...or either 120V or 240V applications The wiring assemblies are designed for maximum efficiency and will work well for almost any layout requirements It is important to note that there are six crimping...

Страница 9: ...uired To add two sheets to an existing sheet use an A2 To add three sheets an A3 will be required An A4 will connect up to four sheets to an existing sheet or sheet set 3 Jumper JP 60 A Jumper can be...

Страница 10: ...erWarm Radiant Heat offers a variety of direct line voltage thermostats in both programmable and non programmable models All EverWarm Radiant Heat thermostats in the United States are GFCI protected r...

Страница 11: ...O N 2 Digital Multi Meter Wire Stripper Wire Cutters Wire Crimper Broom Dust Pan Scissors Tape Measure Flex Heat Crimping Tool Part CHP 01 TOOLS REQUIRED FOR INSTALLATION TOOLS NEEDED WHEN INSTALLING...

Страница 12: ...t water will bead If the sealer is left on the floor the mortar for the tiles won t adhere Remove sealer with a floor sander using medium grit sandpaper 3 There should not be any protrusions sticking...

Страница 13: ...on top of the Heating Film using an unmodified thin set mortar meeting the requirements of ANSI A118 1 to install ceramic and stone tile See notes NOTE EverWarm PRODUCTS LLC DOES NOT RECOMMEND THE US...

Страница 14: ...set and using a roller apply a continuous even pressure with overlapping strokes 5 Install the tile on top of the Heating Film using an unmodified thin set mortar meeting the requirements of ANSI A118...

Страница 15: ...set to the crack suppressant uncoupling mat set the Heating Film onto the thin set and using a roller apply a continuous even pressure with overlapping strokes 4 Install the tile on top of the Heatin...

Страница 16: ...ntinuous even pressure with overlapping strokes making a permanent bond between the sub floor and film 4 Follow the manufacturer s recommended drying time for the membrane you use before starting the...

Страница 17: ...one 2 Prepare the Heating Film according to the steps in the General Installation Instructions beginning on page 24 3 Install the Laminate flooring per manufacturer s installation guide LAMINATE INST...

Страница 18: ...g to its new home lay out the wood floor according to the manufacturer s recommendations This will help mitigate the effects of subsequent expansion and contraction The wood floor manufacturer and ins...

Страница 19: ...for radiant floor heating systems according to the manufacturer s instructions 3 Install the carpet according to the manufacturer s instructions Be sure carpet is approved for installation over radian...

Страница 20: ...the adhesive Using a roller apply a continuous even pressure with overlapping strokes making a permanent bond between the sub floor and film 3 Install the linoleum or vinyl flooring according to the m...

Страница 21: ...the end of the pre assembled attached and pre taped wire Harness These are used for adding another sheet of Heating Film If you are adding a second sheet to your system please refer to Harness Adders...

Страница 22: ...dding a second sheet then proceed to the next step 5 Check the OHMs reading see pg 28 in this Guide 6 A floor sensor MUST be installed and is included with the thermostat See pg 31 in this Guide 7 Aft...

Страница 23: ...thru 32 These kits are all supplied with the CarbonicHeat Film two 2 J 4 Harnesses and sixteen 16 pieces of Edge Sealing Tape This is enough material to complete a 200 square foot room or two 100 squa...

Страница 24: ...d Additionally a pre planned layout will determine thermostat and possibly slave thermostat locations FIRST DETERMINE THE NUMBER OF SQUARE FEET OF HEATING FILM THAT ARE REQUIRED FOR THE INSTALLATION T...

Страница 25: ...HERMOSTAT J 120 HARNESS J 120 HARNESS J2 120 HARNESS J3 240 HARNESS THERMOSTAT A 240 ADDER EXAMPLE OF A 200 SQ FT SYSTEM Qty 1 Thermostat Qty 1 A 240 Adder Qty 1 J3 240 Harness EXAMPLE OF A 100 SQ FT...

Страница 26: ...heat expansion to overlap The thermal expansion for this product is up to three 3 inches from the edge of the active heating area 1 UNDER NO CIRCUMSTANCES SHOULD THE ACTIVE AREAS GRAY OF THE HEATING F...

Страница 27: ...corrected It is important to note that there are six 6 Terminal Crimps per sheet for 120 volt and four 4 Terminal Crimps per sheet for 240 volt system The crimping terminals have 11 lance bayonets tha...

Страница 28: ...ead using a volt meter Compare this measured value to the calculated OHMs in Step 2 This measurement should be done with film at room temperature as temperature affects the resistance reading The inte...

Страница 29: ...ions should be checked for proper contact of the Crimping Terminals to the copper bus bars Resistance should be recorded and a second resistance test should be performed after the flooring installatio...

Страница 30: ...DURING TAPING FOR PATCHING HOLES SLITS CUTS SCRAPES AND ANY EXPOSED GRAY AREA EDGES TAPE MUST BE APPLIED TO BOTH SIDES OF THE FILM DURING TAPING SLIT CUT PATCH NAIL HOLE PATCH HOLE NOTE FAILURE TO PE...

Страница 31: ...ting Film Do NOT place floor sensor directly on the heating area The sensor should be taped to the sheet using a piece of Edge Sealing Tape The sensor wire is to be run to the conduit and up to the th...

Страница 32: ...QUIRED PART OF THE INSTALLATION PROCEDURE THE HEATING FILM CAN ONLY BE INSTALLED ON A DEDICATED ELECTRICAL CIRCUIT S NOT TO EXCEED 80 OF THE BREAKER S RATED CAPACITY POWER IS USED 15 WATTS PER SQUARE...

Страница 33: ...S E C T I O N 6 120 VOLT CONFIGURATION SINGLE SHEET SET UP FLOOR HEAT LOAD FLOOR SENSOR LOAD POWER SUPPLY CONNECTION THERMOSTAT BREAKER BOX WALL BOX THERMOSTAT FLOOR HEAT LOAD FLOOR HEAT LOAD FLOOR SE...

Страница 34: ...LOOR SENSOR LOAD POWER SUPPLY CONNECTION THERMOSTAT BREAKER BOX WALL BOX THERMOSTAT FLOOR HEAT LOAD FLOOR HEAT LOAD FLOOR SENSOR 120 VOLT CONTACT LOCATIONS TWO PANELS 81 2 144 120 VOLT CONFIGURATION M...

Страница 35: ...S E C T I O N 7 FLOOR HEAT LOAD FLOOR SENSOR LOAD POWER SUPPLY CONNECTION THERMOSTAT BREAKER BOX WALL BOX THERMOSTAT FLOOR HEAT LOAD FLOOR HEAT LOAD FLOOR SENSOR 240 VOLT LOCATIONS 40 6 144 240 VOLT C...

Страница 36: ...LOOR SENSOR LOAD POWER SUPPLY CONNECTION THERMOSTAT BREAKER BOX WALL BOX THERMOSTAT FLOOR HEAT LOAD FLOOR HEAT LOAD FLOOR SENSOR 240 VOLT CONTACT LOCATIONS TWO PANELS 81 2 144 240 VOLT CONFIGURATION M...

Страница 37: ...O N 8 FLOOR HEAT LOAD FLOOR SENSOR LOAD POWER SUPPLY CONNECTION SLAVE UNIT THERMOSTAT ZONE 1 ZONE 2 ZONE 3 SLAVE 2 SLAVE 1 SLAVE 3 BREAKER BOX D E D I C A T E D C I R C U I T DEDICATED CIRCUIT D E D...

Страница 38: ...it should stop Thermostat bypassed or switch on The control has the proper wire connections per diagram on back but your multi meter shows full line voltage on the load side of the control when you b...

Страница 39: ...perty the warranty is strictly limited to Product replacement from EverWarm Corporation verified defective or non conforming Product exclusively limited to providing replacement products for any defec...

Страница 40: ...t room will have approximately three sheets for a total of 30 linear feet of Heating Film Divide 218 by 30 yielding a calculated ohms reading of 7 27 FOR 240 VOLT INSTALLATIONS USE THIS FORMULA Exampl...