4.2.
SYSTEM CONFIGURATION
4.2.1. Communication Settings from the Front Panel (Except EQT-3224 and –CS versions)
A shaft encoder and four digit dot-matrix display allow card edge navigation for a set of menus used to
configure the EQT router. To enter the menu system, rotate the shaft encoder in either direction.
On all menus, there are three selectable items:
View, Set
and
End
. Selecting
View
will display the
current value of the item, while
End
will return the display to the main menu. Selecting
Set
will allow the
current setting to be changed.
To adjust any parameter, use the shaft encoder to move up or down to the desired parameter and
press the shaft encoder. The item will be underlined and flashing indicating that you can now adjust the
parameter. Using the shaft encoder, adjust the parameter to its desired value.
When you have stopped at the desired value, press the shaft encoder again. This will update the
parameter to the selected value. Continue selecting and adjusting other parameters. Scroll to the
End
option when you have completed your selection.
The following chart provides a brief description of the menus that are accessible through the front
panel.
QLAD
Sets the Q-Link address of the device.
IPAD
Sets the IP address of the device.
NETM
Sets the subnet mask.
DHCP
Controls the Dynamic Host Configuration Protocol function.
Note: The router must be rebooted in order for network changes to take effect.
4.2.2. Setting the IP Addressing for the EQT Clean Switch
The EQT-3224-3G, EQT-1602-3G-CS, and EQT-3204-3G-CS clean switch routers consist of two, three
and four individual components respectively, each with its own IP address. Each of these devices can
be accessed through the Ethernet port or the Micro-D serial port at the back.
When shipped from the factory, the default IP addresses of the devices are as follows:
1. Router component
192.168.9.190
2. Clean/quiet switch component
192.168.9.191 (Slot1 in EQT-3204 and
EQT-1602)
3. Clean/quiet switch component (for EQT-3204)
192.168.9.192 (Slot2 in EQT-3204)
4. Control panel component
192.168.9.193
Содержание EQT Series
Страница 2: ...This page left intentionally blank ...
Страница 8: ...EQT Router User Manual Page ii Revision 1 9 1 This page left intentionally blank ...
Страница 14: ...EQT Router User Manual Page viii Revision 1 9 1 This page left intentionally blank ...
Страница 34: ...EQT Router User Manual Page 20 Revision 1 9 1 This page left intentionally blank ...
Страница 70: ...EQT Router User Manual Page 56 Revision 1 9 1 This page left intentionally blank ...
Страница 76: ...EQT Router User Manual Page 62 Revision 1 9 1 This page left intentionally blank ...