7890MG Series
Universal Media over IP Gateway for 10 x ASI/SD/HD/3G/GE
Page - 24
Revision 0.2
VISTALINK
®
PRO
Traps
Video Output Loss:
Triggers when video was present and is now Lost. When no video is present,
this indicator will be red.
Video Output Error:
Triggers when the video output has errors.
Video Output Standard Change:
Triggers when the video output standard has changed.
Trunk A In Use:
Triggers when the incoming IP stream on Trunk A is in use for this port.
Trunk B In Use:
Triggers when the incoming IP stream on Trunk B is in use for this port.
Video Stream Sequence Error:
Triggers when there is a video output sequence count error.
Video Stream Crc Error:
Triggers when there is a Video Output CRC Error.
Video ASI Output CC Error:
Triggers when there is an ASI Continuity Count Error detected on
output.
Video ASI Output Sync Error:
Triggers when there is an ASI Sync Error Fault.
Video Output Hitless Not Ready:
Triggers when hitless switching is not currently available on the
selected port. Not having both Trunks plugged in for example could cause this fault.
Trunk A Stream Loss:
Triggers when the IP stream for this port is lost on Trunk A.
Trunk B Stream Loss:
Triggers when the IP stream for this port is lost on Trunk B.
Trunk A Rx Stream IP Change:
Triggers when a change is made to the IP stream settings for this
port on Trunk A.
Trunk B Rx Stream IP Change:
Triggers when a change is made to the IP stream settings for Trunk
B.
Содержание 78908MG-10GE2