5-1 : Location of Jumpers – 7703BPX-DC-RF
5.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME
STATUS
The FRAME STATUS jumper J9 located near the top front of the module determines whether local
faults (as shown by the Local Fault indicator) will be connected to the 7700FR frame's global status
bus.
FRAME STATUS:
To monitor faults on this module with the frame status indicators (on the Power
Supply FRAME STATUS LED's and on the Frame's Fault Tally output) install this jumper
in the On position. (Default)
When this jumper is installed in the Off position local faults on this module will not be
monitored.
5.2.
MONITORING AND CONTROL OF 7703BPX-DC-RF CARDS THROUGH SNMP
OR CARD EDGE MENU SYSTEM
The card does not require any reconfiguration or adjustment to monitor and control through SNMP or
the card edge menu system. Updates to configuration and status are visible in both systems.
5.3.
CONFIGURING THE MODULE FOR FIRMWARE UPGRADES (7703BPX-DC-RF ONLY)
UPGRADE:
The UPGRADE jumper J12 is used when firmware upgrades are being done to the
module. For normal operation it should be installed in the
RUN
position. See the
Upgrading Firmware
chapter in the front of the manual binder for more information.