7703BPX-DC-RF
2X1 RF Protection Switch
Revision 1.0
Page 5
3.
SPECIFICATION
3.1.
RF INPUT/OUTPUT
Inputs
2
Outputs
1
Connectors
1 BNC per IEC 61169-8 Annex A (F type and SMA optional)
I/O Impedance
75Ω, 50Ω optional
Frequency Response
10MHz - 2250MHz
< ±0.75dB
Insertion Loss
10MHz - 2250MHz
< 2 dB
Return Loss
> 10 dB
Isolation
> 45 dB
Input Power Range
0dBm to –50dBm
3.2.
GENERAL PURPOSE INPUTS
Number of Inputs
2
Type
Opto-isolated, active low with internal pull-ups to +5V
Connector
2 pins plus ground on 6 pin removable terminal strip
Signal Level
+5V Pullup
Low: -5 to +2.5 VDC, High: 3.5 to 10 VDC
+12V Pullup
Low: -5 to +9.5 VDC, High: 10.5 to 15 VDC
Max Sink Current
(input shorted to ground) 15 mA
Max Leakage Current for input High
200 µA
3.3.
GENERAL PURPOSE OUTPUTS
Number of Outputs
1
Type
“Dry Contact” relay contacts - normally open and normally closed contact
provided
Connector