570FEC-HW-X19
Bulk 10GE FEC Encode/Decode
Revision 1.0
Page - 13
4.3.2. Backup Input Port Control
For FEC-Rx1 to FEC-Rx32
Backup input Stream Alias:
This field allows the user to set the back up input alias name.
Backup SFP Port Selection:
This dropdown allows the user to select the SFP where each channel will
obtain their backup stream source from.
Backup input IP Address:
This field allows the user to set the backup input IP address/multicast
address.
Backup input IP Port Number:
This field allows the user to select the input UDP port number.
Backup input IGMPV3 Mode:
This parameter allows the user to include/exclude the backup IGMP V3
to use.
Backup IGMPV3 SSM Src1-6 IP Address:
This field allows the user to set the IP addresses which will
be used while forming the source filter for IGMPV3 communications.
Backup Input RTP Present:
This field displays the backup input RTP presence status.
Figure 4-8: WebEASY
®
- FEC Correction Control Section (Part 2 of 3)