3
Maintenance Menu
71
EVERSYS AG
CP89 Rue du Biais 19 CH-1957 Ardon
3
Adjust the “Carbonate hardness” and the “Total hardness”.
4
Adjust the “Bypass” of your water filter according to the informa-
tion provided by the software.
5
Activate and start the water counter “Start Counter/Reset”.
6
Deactivate the water filter control by selecting “Other Filter” and
set “water filter capacity” to 0 L.
8.2
SERVICE PARAMETERS
•
This function allows an automatic warning when servicing the
machine is needed.
•
Default parameters are set up at 100,000 cycles or 12 months.
This setting can be adjusted according to your service strategy.
NOTICE
Notice
Water filters not properly adjusted will invalidate the warranty
!