Click three times quickly on the tamper switch behind the battery cover or a detected action by the sensor
will wake up the device and keep it awake.
It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to
go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup.
Node Information Frame
NI
The Node Information Frame is the business card of a Z-Wave device. It contains information
about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed
by sending out a Node Information Frame. Beside this it may be needed for certain network operations to
send out a Node Information Frame.
Click three times quickly on the tamper switch behind the battery cover or a detected action by the sensor
sends a Node Information Frame.
Associations
A
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling
another device is called association. In order to control a different device, the controlling device needs to
maintain a list of devices that will receive controlling commands. These lists are called association groups
and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event
happens all devices stored in the respective association group will receive a common wireless command.
Association Groups:
1 Devices controlled by open/close events (max. nodes in group: 5)
Command Classes
Supported Command Classes
Basic (version 1)
Battery (version 1)
Wake Up (version 1)
Association (version 1)
Version (version 1)
Binary Sensor (version 1)
Alarm (version 1)
Manufacturer Specific (version 1)
Controlled Command Classes
Basic (version 1)
(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6