8. If the slats fail to reach a full turn, or the blinds starts to move up, repeat steps 4
to 6 with a new time until satisfied.
Operation
On demand control
The controller can be operated on demand either;
- manually using the external switches on terminals SW1/SW2, or
- remotely through the gateway.
To control from Homesys,
1. Go to “Automation” page, under “Devices” tab.
2. Move the slider to set the curtain position.
3. For blinds, the full turn of the slats are divided into 6 levels. Click on the “Tilt
level” to choose the desired angle of tilt.
Scenes
The controller can added as part of a Scene.
1. Go to “Automation” page, select “Scenes” tab.
2. Select a Scene, and click on its “Action” tab to set the curtain position, and if
necessary, the slats tilt angle for blinds.
Troubleshooting
Symptom
Cause of Failure
Recommendation
Device not responding and
LED not displaying
The device is not wired to
the mains power correctly
Check if wiring is correct, or
voltage is too high or too low
LED displaying, but cannot
control curtain.
Binding was not successful
Repeat the steps in Binding with
HomeSys
Reset to Factory Settings
To reset the unit back to factory default state:
1. Make sure the LED on the unit is turned off. If it is on, press the Link key once to
turn it off.
2. Press and hold the Link key on the module for 3 seconds until the LED turns on
and then release. The LED will start to flash.
3. Press and hold the Link key again for more than 6 seconds until the LED turns
off, then release. The LED will flash every 2 seconds indicating the unit is now
reset back to factory default settings.
Auto Binding
Once reset back to factory settings and first powered up again, the unit will attempt
to automatically bind with any U-Net compatible gateway for 30 seconds. This is
called Auto-binding.
If binding is unsuccessful after 30 seconds, Auto-binding process will stop and the
LED indicator will flash slowly every 2 seconds, implying this unit has never paired
with any device.
Note: Auto-binding can be restarted again by disconnecting and reconnecting
power to the unit.
Specifications
Frequency Range
868.3 MHz
Power Input
230V/50Hz
Maximum Electric Motor
Load
Max. 400W
Working Temperature
-10°C - 40°C
Specifications are subject to change without notice