background image

 

8.  If the slats fail to reach a full turn, or the blinds starts to move up, repeat steps 4 

to 6 with a new time until satisfied. 

 
Operation 
 

On demand control 

The controller can be operated on demand either; 
-    manually using the external switches on terminals SW1/SW2, or 
-    remotely through the gateway. 
 
To control from Homesys, 
1.  Go to “Automation” page, under “Devices” tab. 
2.  Move the slider to set the curtain position. 
 
 
 
 
 
3.  For blinds, the full turn of the slats are divided into 6 levels. Click on the “Tilt 

level” to choose the desired angle of tilt. 

 

Scenes 

The controller can added as part of a Scene. 
1.  Go to “Automation” page, select “Scenes” tab. 
2.  Select a Scene, and click on its “Action” tab to set the curtain position, and if 

necessary, the slats tilt angle for blinds. 

 

 
 
 
 
 
 
 
 
 

Troubleshooting 
 

Symptom 

Cause of Failure 

Recommendation 

Device not responding and 
LED not displaying 

The device is not wired to 
the mains power correctly 

Check if wiring is correct, or 
voltage is too high or too low 

LED displaying, but cannot 
control curtain. 

Binding was not successful 

Repeat the steps in Binding with 
HomeSys 

 

Reset to Factory Settings 

To reset the unit back to factory default state: 
1.  Make sure the LED on the unit is turned off. If it is on, press the Link key once to 

turn it off. 

2.  Press and hold the Link key on the module for 3 seconds until the LED turns on 

and then release. The LED will start to flash. 

3.  Press and hold the Link key again for more than 6 seconds until the LED turns 

off, then release. The LED will flash every 2 seconds indicating the unit is now 
reset back to factory default settings. 

 

Auto Binding 

Once reset back to factory settings and first powered up again, the unit will attempt 
to automatically bind with any U-Net compatible gateway for 30 seconds. This is 
called Auto-binding. 
 
If binding is unsuccessful after 30 seconds, Auto-binding process will stop and the 
LED indicator will flash slowly every 2 seconds, implying this unit has never paired 
with any device. 
Note:  Auto-binding  can  be  restarted  again  by  disconnecting  and  reconnecting 
power to the unit. 
 

Specifications 

 

Frequency Range 

868.3 MHz   

Power Input 

230V/50Hz   

Maximum Electric Motor 
Load 

Max. 400W 

Working Temperature 

-10°C - 40°C 

 

Specifications are subject to change without notice 