background image

AN148 

 ON/OFF MODULE 

 

This AN148 plug-in ON/OFF Module is a transceiver which is a Z-Wave

TM

 enabled 

device  and  is  fully com patible  with a ny  Z-Wave

TM

  enabled  network.  Z-Wave

TM

 

enabled devices displaying the Z-Wave

TM

 logo can also be use d with it regardless 

of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave

TM

 

enabled  networks. Remote  On/Off  control of the   connected  load is possibl e  with 

other  manufacturer’s  Wireless  Controller.  Each mod ule  is  designed  to a ct  as  a 

repeater.    Repeaters  will  re-transmit  the  RF  signal  to ensu re  that  the sig nal  is 

received  by i ts  intended  destination  by  routing  the  signal  around  obstacles  and 

radio dead spots. The AN148 plug-in ON/OFF Module is compatible with our 

Motion Detectors SP103 and Door/Window Detectors SM103. 

 

Adding to Z-Wave

TM

 Network 

 

In the front  casing, there is an On/Off knob which is used to carry out inclusion, 

exclusion  or  association.  Put a   Z-Wave

TM

  Wireless  Controller  into 

inclusion/exclusion  mode,  press the kno b  on the Module to compl

ete  the 

inclusion/exclusion process. 

 

 

 

 

 

 

 

 

 

Installation 
 

1.  Plug this On/Off Module into a wall outlet near the load to be controlled. 

 

2.  Plug  the l oad  into the   Module.    Make  sure  the lo ad  to b e  controlled  cannot 

exceed 2990/3500 watts. 

 

3.  Turn the knob or switch on the load to the ON position. 

 

4.  To manually turn O N the On/Off Module, press and  release the On/Off knob. 

The red indicator LED will turn ON, and  the load plugged into the  Module will 

also turn ON. 

 

5.  To manually turn OFF the Module, simply press and release the On/Off knob. 

The red indicator LED will turn OFF and the load plugged into the Module will 

also turn OFF. 

 

6.  If  Motion D etector  SP103 or Doo r/Window  Detector  SM103 has bee n           

removed from the wall by triggering the tamper switch, the Detector (SP103 or 

SM103)  will  send  an  alarm  command 

(ALARM_REPORT, Alarm Type == 

0x01, Alarm Level == 0x11) 

to the Module, of which red indicator LED and the 

load plugged into the Module will be on and off intermittently for 10 seconds. 

 

Note:

 When putting Motion Detector or Door/Window Detector in use, do not  

connect  the load bel ongs  to motor or electroni c  transformers,  as the loa d 

would be impaired. 

 

Programming 

 

The On/Off knob allows the user 

-  Turn on or off the load attached 

-  Include or exclude the Module from the Z-Wave

TM

 system 

-  Control other Z-Wave

TM 

enabled devices 

 

See the instructions for SP103 Motion Detector or SM103 Door/Window Detector. 

   

Troubleshooting 

                                   

Symptom 

Cause of Failure 

Recommendation 

The Module not working and 

LED off 

1.  The Module is not 

plugged into the 

electrical outlet 

properly 

2.  The Module is out of 

order 

1.  Check power connections 

2. Don’t open up the Module and 

send it for repair. 

The Module LED illuminating, 

but cannot control the ON/OFF

Switch of the load attached 

Check if the load plugged 

into the Module has its 

own ON/OFF switch 

Set the ON/OFF switch of the 

load attached to ON 

The Module LED illuminating, 

but the Detector cannot control

the Module 

1. Not carry out 

association 

2. Frequency interference

1. Carry out association 

2. Wait for a while to re-try 

 

 
Socket Type 
 