3
Reset to Factory Settings
To reset AN132 back to factory default state:
1.
Press and hold the On/Off button for 3 seconds until the LED starts to flash then
release the button.
2.
Within 30 seconds, press and hold the button for more than 6 seconds. The LED
will start to flash, implying the device is reset back to factory mode
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact
your original retailer or nearest service center if the below solutions cannot solve your
problem.
Symptom
Cause of Failure
Recommendation
The unit is not working and
LED is off.
1. The unit is not connected
well to the power socket or
extender.
2. The unit is out of order.
1. Try to connect again and
make sure the extender is
working fine.
2.
Don’t open up the unit and
send it for repair.
The unit is working, but
cannot control the ON/OFF
status of the device
connected to the unit.
Check if the device connected
to the unit has its own on/off
switch.
Set the switch of the
connected lamp to On/Off.
The LED is on but cannot
control the unit.
1. The unit
didn’t complete
successfully the binding
operation.
2. The unit cannot
communicate with the
gateway HSC04.
1.
Check “Manual binding”.
2. Place the plug closer to the
gateway.
The LED flashes rapidly for
30 seconds and the unit
cannot be controlled.
Overload occurred.
Remove the load and ensure
the connected load does not
exceed 2000 VA and current
does not exceed 14.5A.
LED Table
The table below describes the LED indication at various stages of Plug operation.
LED indication
Stage
Explanation
LED blinks
rapidly for 30
seconds
(blinks every 1
second)
1.During 30 seconds
after plugged into
electrical outlet
The Plug enters Binding
mode for 30 seconds to bind
with Gateway.
If binding is successful, the
LED will turn on for 1 second
then off.
If binding fails, the LED
flashes rapidly for 3 times at
the end of 30 seconds.
2. After entering Manual
Binding mode
LED blinks
slowly for a
long period.
(blinks every 2
seconds)
1. More than 30 seconds
have passed after
plugging into electrical
outlet
Binding with Gateway has
failed. The Plug is still in
factory reset status.
2. After reset to factory
default
The Plug is in factory reset
status.
LED turns On
After short button press
Plug turns on the load.
LED turns Off
After short button press
Plug turns off the load.
LED flashes
rapidly for 30
seconds
After plug turns on the
load
Indicates overload protection
is activated.
Specifications
Frequency Range
868MHz (EU)/ 923MHz (America)
Operating Voltage
230V/50Hz
Maximum Load
2000 Watts
Overload Protection
2200 Watts (±1%)
Protection Degree
IP20
Range
70 meter min. line of sight
** Specifications are subject to change without notice.