5-20 U p p e r t h r e a d t e n s i o n
adjustment
1) Set the tension dial (A) to "4". (2)
2) Use a dial tension gauge (150g) (B) to
take measurement. (1)
3) Put dial tension thread into gauge's
hook and pull, and the standard range
should be 60 ~ 80g.
4) If the range is not between 60
~ 80g,
adjust tension by turning plastic dial (a)
forward / backward. (2)
Forward
weaker
Backward
stronger
5) Re-check tension by above step 1, 2, 3.
A
backward
forward
A
a
Forward
Backward
B