INSTALLATION INSTRUCTIONS 

(continued)

7.  Shut off the system inlet valve located on the inlet of the prefilter head.
8.  Check to be sure the O-ring on the prefilter housing is sufficiently lubricated. 

Use a good grade of silicone lubricant, if needed. Position the prefilter  

cartridge on guide seat in the bottom of the bowl. Then thread the bowl into  

the head by hand. Use a sump wrench to snug the bowl onto the head.

9.  Install the carbon filter cartridge(s) into the filter head(s) following directions 

on the cartridge label or as shown in the Cartridge Change illustrations.

10. Turn on inlet water to the filter system and check for leaks.
11. Open the flushing valve and flush the cartridge(s) by running water through at 

full force for ten (10) minutes. This will set the filtering media and purge any 

air and fines, insuring maximum filter life. See illustrations.

12. After flushing, close the flushing valve, turn on power to equipment. The 

system is ready for operation.

FLUSHING

For maximum life, all carbon filter cartridges must be flushed for fen (10) minutes 

at full flow before use. 
ALL NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE 

BEFORE BEING PUT INTO SERVICE!
If the cartridges are new, have been properly flushed and both needle and follower 

register inadequate pressure, or the LPA is sounding, you may be experiencing 

inadequate water pressure or some restriction may exist in the inlet water line. In 

either case, the incoming water pressure must be improved to receive optimum 

filter life.
COMPLETE CARTRIDGE CHANGE INSTRUCTIONS CAN BE FOUND ON THE FILTER 

CARTRIDGE LABEL.

CARTRIDGE CHANGE DETERMINATION

Replace the prefilter cartridge whenever it becomes excessively dirty (observed 

visually or by flow restriction). Follow the change instructions provided with the 

cartridge. Replace filter cartridges when capacity is reached, or when flow becomes 

inadequate, but at least annually. All filter cartridges on multiple cartridge systems 

should be changed at the same time. The system pressure gauge or accessory (sold 

separately) Everguard Low Pressure Alarm (LPA) provide a quick, simple means of 

determining when the filter cartridge(s) should be checked. Installed on the system 

outlet manifold, the gauge or LPA can be used to monitor both dynamic (flowing) 

and static (line) pressure. The cartridge(s) should be changed when the pressure 

gauge needle is in the red area while equipment is in operation, and yet the needle 

shows adequate line pressure between cycles. Observe the needle during the next 

equipment on cycle. If the needle registers adequate pressure, it can be assumed 

that the temporary low-pressure condition was caused by a brief power failure or 

other incoming pressure disruption. If the low pressure condition is not due to an 

external condition, check/change the prefilter first. If the low pressure condition is 

still not corrected, change the filter cartridges.

REPLACEMENT PARTS

Contact your local Pentair

®

 Everpure

®

 Dealer for filter cartridges or system replacement parts.

Part Number

Description

Part Number

Description

Part Number

Description

System Replacement Parts

EV3114-09

Outlet Pressure Gauge (All Systems)

EV3122-48

Insurice Twin, Triple & Quad Flush Valve

EV9606-01

7SI Replacement Cartridge 1 PK

EV3114-09

Inlet Pressure Gauge (PF Twin, Triple & Quad Flush) EV3112-40

O-Ring for Prefilter Bowl

EV6001-07

Everguard Low Pressure Alarm 115V

EV3114-07

Inlet Valve (All Systems)

153194-06

20" Prefilter Bowl

EV3102-01

Insurice Single PF Flush Valve

EV9534-26

20" Prefilter Replacement Cartridge 6 PK

 2 

7SI INSURICE

®

 PF SYSTEMS INSTRUCTION & OPERATION GUIDE

Figure 1 - Insurice PF Single - 7SI System

25"

14"

INLET

3/4" FNPT

Primary 

Filter

Cartridge

Prefilter

(Inside Sump)

25" 

(63.50 cm)

14" 

(35.56 cm)

Figure 2 - Insurice Twin PF - 7SI System

25.59"

21.5"

INLET

3/4" FNPT

OUTLET

3/4" FNPT

21.5" 

(54.61 cm)

25.59" 

(65.0 cm)

Figure 3 - Insurice Triple PF - 7SI System

Outlet

3/4" FNPT

INLET

3/4" FNPT

25.75"

25.59"

25.75 

(65.41 cm)

25.59" 

(65.0 cm)

Figure 4 - Insurice Quad PF - 7SI System

29.365

25.59

29.365" 

(74.59 cm)

25.59" 

(65.0 cm)