COLDRINK SERIES INSTALLATION AND OPERATION GUIDE
REPLACEMENT PARTS
Contact your local Pentair
®
Everpure
®
dealer for system
replacement parts.
DESCRIPTION
PART NUMBER
Outlet Pressure Gauge
EV3114-09
Inlet Pressure Gauge
(Coldrink 3 & 4)
EV3114-09
Inlet/flushing Valve
EV3114-07
O-ring for Prefilter
EV3112-40
Prefilter Bowl
EV3112-38
System Tested and Certified by NSF International against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42 —
Aesthetic Effects
Bacteriostatic Effects
(MC
2
and XC
2
only)
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
(MC, MC
2
, XC, XC
2
only)
Standard No. 53 —
Health Effects
Mechanical Filtration
Cyst (MC, MC
2
, XC, XC
2
only)
Asbestos (MC and MC
2
only)
CARTRIDGE CHANGE PROCEDURE
E-Series Prefilter Cartridge Change
1. Shut off power to equipment. Shut off
inlet water ahead of system.
2. Push red relief valve. Unscrew bowl.
Remove prefilter cartridge.
3. Clean bowl with filtered water only; NO
SPECIAL CLEANERS.
4. Feel head o-ring. If dry, lubricate with
high quality silicone lubricant.
5. Install new prefilter cartridge in bowl.
Hand tighten bowl onto head.
6. Turn on water. Turn on power to
equipment.
Everpure Carbon Filter Cartridge
Change
1
. Shut off power to equipment. Shut off
inlet water ahead of system.
2. Open flushing valve to relieve pressure.
3. Hold head firmly and push upward. Turn
cartridge to left until it stops.
4. Pull cartridge downward and out of head.
5. Hold head firmly. Align cartridge lug with
label. Insert new cartridge firmly
into head.
6. Turn cartridge right 90˚ until
rotation stops.
7. Repeat steps 3-6 for remaining
cartridges.
Flushing
8. With flushing valve fully open, open inlet
water at full force for five minutes. Close
flushing valve.
9. Turn on power to equipment
PRESSURE GAUGES
Low Inlet
Pressure
Adequate Inlet
Pressure
Low Outlet
Pressure
Adequate Outlet
Pressure