background image

24

 

Component Identification and Explanation

 

Control Panel Layout 

Number  Component  Identification 

Value 

Function/Component Note 

6

 

Adjustment Knob

 

NA

 

Used to adjust any parameter in the parameter/weld cycle graph found in item # 3. IMPORTANT! With the 

knob in the normal position, the knob adjusts incrementally.  However, for a greater adjustment value, 

such as a whole number at a time rather than decimals, or to increase in values of 10 (depending on 

function type) press in on knob lightly and turn the knob while holding pressure in.

 

7

 

Stick Function

 

 

Rather than have the stick function attached to the weld cycle graph, the functions are separated here.  In 

Stick mode use # 5 to select and adjust Arc Force, Hot Start Time (Duration), or Hot Start Amps (Intensity)

 

9

 

Pulse

 

OFF

 

Standard AC/

DC

 

Adv. AC

 

This unit provides two types of Pulse for TIG.  The Standard mode operates pulse in both AC and DC 

output modes in a traditional manner, alternating the Amperage between two values, of the same type of 

output.  The AC Advanced pulse not only alternates Amperage it also alternates between both AC and DC 

output, with the AC being assigned the 

Peak

” 

Amp value (Welding Amps) and the 

Base Amp

” 

value 

(Pulse Amps).  This offers a hybrid, or rather a mixed type of pulse.  See next section for further explana-

tion and details of operation.  See Specifications page for range of value for each pulse parameter.  This 

parameter does not function with Stick mode.

 

9

 

Remote Function

 

2T

 

4T

 

Pedal

 

2T Pedal

 

4T Pedal

 

The user may select between 2T, 4T,  Pedal, 2T with Pedal, and 4T with Pedal.  2T and 4T modes should 

only be used with the torch switch.  Pedal mode should only be used with the Foot Pedal.  2T and Pedal 

as well as 4T Pedal  modes (where both lights are lit) is designed to be operated mainly with a torches that 

have both a switch for activating the arc, and a separate amp control on the torch.  If a slider or a rotary 

control is used without a separate switch, select Pedal mode only.  If  2T  and Pedal, or 4T and Pedal are 

lit together and used with the foot pedal, or slider or similar amptrol, malfunction may occur.  In Pedal 

mode, certain features  like Up

-

Slope and Down Slope, will not allow adjustment and will be zeroed out 

(null value).

 

10

 

Wave Form Control

 

Advanced 

Square

 

Soft Square

 

Triangular

 

Sine

 

This  is used to select from four  wave form selections offered in AC mode.  It is also used to select the 

unit to weld in DC mode.   Each wave form has an affect on bead profile, wet

-

in speed, arc softness, and 

weld characteristics in general.  For most Aluminum applications Advanced Square Wave Form will be 

used.  DC will be used for all metals except Aluminum and Magnesium.  There is no wave form selection 

for DC.

 

11.

 

Display

 

A,S, %, Hz or

 

Error

 

The display will display the corresponding value of each parameter selected for adjustment. The display 

reading may represent  a value in Amps, Seconds, Percent, or in Hertz (Frequency).  It can also indicate a 

malfunction or error present.  The LED corresponding to the parameter selected for adjustment will be lit 

to indicate exactly what value is being represented. (ie, Hz, Time, etc.) The default reading will always be in 

Amps. The display will revert to Amps after 3 seconds if no adjustment to the selected parameter is made.

 

10 

11 

Содержание PowerTIG 200 EXT

Страница 1: ...erlast Power Equipment AC DC AC DC PULSE ADV AC PULSE AC WAVE FORM CONTROL DC 240V 1 3 Phase Welders Plasma Cutters Multi Process Safety Setup and General Use Guide FUNCTION AC DC TIG with Pulse Funct...

Страница 2: ...PACKING YOUR UNIT AND INSPECTION 12 CONNECTING YOUR UNIT TO THE POWER SOURCE AND WIRING INFORMATION 13 SHIELDING GAS INFORMATION AND CONNECTION OF REGULATOR 14 TUNGSEN SELECTION AND GRINDING 15 CONNEC...

Страница 3: ...sation or business by any Everlast employee or subsidiary The owner of this product assumes all liability for its use and maintenance Everlast Power Equipment INC does not warrant this product or this...

Страница 4: ...s unit to work as soon as possible Any issue should be reported within 48 hours 72 if on the weekend or holiday Everlast will not be liable for any shipping after that time What to do within the next...

Страница 5: ...cessories are covered by a separate warranty and detailed infor mation can also be found at the link above Canada Customers Only For full details on the 3 year parts and labor warranty terms of sale a...

Страница 6: ...use this machine until proper training has been received While accidents are never planned preventing an accident requires careful planning Stay alert Please carefully read this manual before you ope...

Страница 7: ...steel toe leather shoes and long sleeved flame resistant clothing i e denim Do not wear Poly Nylon blend materials DANGER Welding poses shock and electrocution risks Keep this welding equipment dry D...

Страница 8: ...degrease metal scheduled to be welded or other related equipment in the area being welded The heating of this cleaner and its residue will create highly toxic phosgene gas Small amounts of this vapor...

Страница 9: ...inimize direct skin and eye exposure to this intense form of radiation by using proper PPE and sun screen where appropriate CAUTION Do not allow bystanders Do not allow others without proper Personal...

Страница 10: ...RNING Do not start or stop the generator with the welder switched on Never use the generator in ECO mode or an auto idle mode Even with a clean power rated generator this action can damage the unit Tu...

Страница 11: ...F Current Rating Rated Amps 240V 1Ph 30A 240V 3Ph 27A 480V 3ph See panel OCV 70V with VRD 24V TIG Duty Cycle Maximum Output Rated at 40 C 104 F 35 325A 60 250A 100 200A Stick Duty Cycle Maximum Output...

Страница 12: ...ies shielding gas customer supplied and conduct live testing of all the functions and features of the machine For testing and welding make sure work clamp is connected directly to the part being welde...

Страница 13: ...rated amperage and duty cycle Do not modify or attempt to changeably between single and three phase service For single phase 240V connection select a NEMA 6 50 Plug and Receptacle for operation This...

Страница 14: ...fficult to identify issues An Argon cylinder is the same type of cylinder as an Argon CO2 cylinder used for MIG and sometimes times can get mixed in and relabeled as pure argon Another increasingly co...

Страница 15: ...ts outside the US due to a small radiation risk posed as an alpha emitter Do not use the following types of Tungsten Pure Tungsten Green Band This will create arc instability The tungsten will not sta...

Страница 16: ...elder or an early invert er you were probably balling the tungsten when welding on AC In fact tons of literature exist about proper size ball how to ball etc In fact well meaning instructors and seaso...

Страница 17: ...at low am perages is the best solution The tip angle and grind preparation will ultimately affect amperage carrying capability of the tungsten Machine wave form can also affect it Each type of Tungste...

Страница 18: ...h There is no safe amp limit for operation with out water If you have a water cooled torch and no cooler you must order a cooler before you use the torch or purchase a separate air cooled torch If an...

Страница 19: ...ll welding rods weld primarily in DCEP DCEN DC Electrode Nega tive although an older term is sometimes called Straight Polarity There are a few rods like E6011 which can operate either way but the pre...

Страница 20: ...to 5 passes may be required Additionally beveling of the joint is required for complete joint penetration even at higher amperages The thickness rating takes into account the heat sink capability of...

Страница 21: ...al for most Stick welding applications 3 Shielding Gas Connector Quick Connect 9mm tube Type 21 Single Shut off Type for Inert Gas Ref EV 9MM B QUICKCONNECT STDSET or 21KATS09MPX 4 Positive Terminal D...

Страница 22: ...effort to mitigate any electrical interference that may be caused by the HF start of this unit 4 Shielding Gas Inflow Connector 5 8 CGA North America 5 8 CGA connector Other Markets Hose Barb connect...

Страница 23: ...they occur in the welding cycle Use the select button 5 to select and highlight a parameter for adjust ment Actual changes to the operating parameters are made with the adjustment knob 5 Some adjust...

Страница 24: ...th Pedal and 4T with Pedal 2T and 4T modes should only be used with the torch switch Pedal mode should only be used with the Foot Pedal 2T and Pedal as well as 4T Pedal modes where both lights are lit...

Страница 25: ...just the balanced between the positive and negative cycles allows more penetration with less amps narrower less un sightly cleaning lines and the ability to weld without a ball on the end of the tungs...

Страница 26: ...er to hold a tight arc and maintain better control DC Direct Current Used to weld Steel Stainless Steel Inox Chrome Moly Titanium and more Not used with Aluminum and Magnesium Down Slope This is a fun...

Страница 27: ...gram ming in 2T and 4T mode or with the foot pedal Post Flow Post Flow is the amount of time in seconds that the shielding gas flows after the arc is terminated This is an important function The flow...

Страница 28: ...Base Amps is the low Amperage value of the pulse When you adjust the base Amps in pulse mode you are actually setting a ratio of base Amps to peak welding Amps Base amps are expressed as a percentage...

Страница 29: ...welding Aluminum The AC portion of the pulse when properly adjusted provides ade quate cleaning action in front of the DC portion of the cycle which comes on to provide penetration in the area just cl...

Страница 30: ...sed to termi nate the arc and begin post flow Shielding Gas Shielding Gas is necessary while TIG welding The shielding gas used for the TIG process is 100 Argon Shielding gas protects the weld from ox...

Страница 31: ...nverter with fast switching times the need for HF overlay used in the older transformers to prevent arc outages at 60 times a second has been eliminated This arc does not excel in di rectability but m...

Страница 32: ...13N21 1 0mm 2 Collet 1 16 NVA13N22 2 13N22 1 6mm 2 Collet 3 32 NVA13N23 2 13N23 2 4mm 2 Collet 1 8 NVA13N24 2 13N24 3 2mm 3 Torch Body Handle 9 or 20 Call for Application Varies by Type 4 Heat Shield...

Страница 33: ...2 13N21 1 0mm 2 Collet 1 16 NVA13N22 2 13N22 1 6mm 2 Collet 3 32 NVA13N23 2 13N23 2 4mm 2 Collet 1 8 NVA13N24 2 13N24 3 2mm 3 Torch Body Handle 9 or 20 Call for Application Varies by Type 4 Heat Shie...

Страница 34: ...e High Foot Pedal 10k 22k Note This unit is designed to accept several different Ohm values including the older 47K 50K Ohm pedal without significantly affecting operation The pinout of the pedal is u...

Страница 35: ...cable is correct length and size Internal unit fault or low input voltage Possible issue running on generator with dirty power Identify cause plug directly into the receptacle Cycle the switch one tim...

Страница 36: ...n 1 4 Reduce amperage or increase tungsten size 8 Porosity of the Weld Discolored weld color Tungsten is discolored Low flow rate of shielding gas High flow rate of shielding gas Tungsten stick out is...

Страница 37: ...between the points Access may be tight but try several angles to get the feeler gauge in between the points The gap should be set to anywhere between 030 and 045 with 035 being preferred 5 If adjustm...

Страница 38: ...38...