A/ INSTALLATION AND GENERAL INFORMATION
1/ Installation

Locate the controller near a  230 V, 50 Hz power source. The
controller must be connected to an electrical installation that
conforms to standards and is protected by a fuse in the 
electrical panel. Select a sheltered location where the controller
will not be spattered by water.

Remove the "knock out" disk(s) in the bottom of the
controller cabinet.

SI-RR+

OUTDOOR WALL MOUNT

25 cm

2

1

3

4

6

7

Not included

230 V

5

ø 4 mm

6 mm

ø 4 mm

2

DOC SI-RR+ ANG OK der  3/06/03  10:22  Page 1

Содержание SI-RR+

Страница 1: ...al installation that conforms to standards and is protected by a fuse in the electrical panel Select a sheltered location where the controller will not be spattered by water Remove the knock out disk...

Страница 2: ...ler has an electrical overload short circuit protection system which only shuts down the station with the electrical problem Example station 3 has a problem The number 3 will appear on the LCD along w...

Страница 3: ...le Connect it to the front panel by slightly inclining the module and then use the screw provided to secure it 4 Replace the front panel and screw it into place 5 Reconnect the 230VAC power supply wir...

Страница 4: ...r underground low voltage use Select the suitable wire size All connections to the valve leads and any wire splices in the field must be water tight Use Rain Bird Quick Connect connectors DBY DBR See...

Страница 5: ...g used If unused stations are not jumpered and the controller reverts to the default program after a lengthy power outage the pump will operate with no flow deadhead Serious pump damage will accur 6 5...

Страница 6: ...5 Connect the transformer wires to the mother board as shown in diagram 5 6 Replace the front panel and screw it into place 7 Reconnect the 230VAC power supply wires Note the controller takes into ac...

Страница 7: ...GB 7 Rain Check TM Option 8 RSD BEx Option Wire in same conduit Wire in same conduit A Wire in same conduit Wire in same conduit Blue wire not used A S S S S DOC SI RR ANG OK der 3 06 03 10 22 Page 7...

Страница 8: ...3 68 CEE of 22 07 93 N 89 336 CEE of 03 05 89 modified by directives N 92 31 CEE of 28 04 92 and N 93 68 CEE of 22 07 93 and conforms to the following standards EN 60065 ed 93 for electrical safety EN...

Страница 9: ...rogram B for flowers watering every day at 9 00 Program C for low volume irrigation every day Each station is assigned to either program A or program B or program C DELAY BETWEEN STATIONS dL You can p...

Страница 10: ...C program by pressing the ABC key Prog A or Prog B will appear in the upper left corner of the display Use the key to move the square through the days of the week 1 Monday Note that the numbers blink...

Страница 11: ...0 00 to 23 59 To cancel a start time repeatedly press the key slowly to display the start times When you see the start time you want to cancel hold down the key for at least 2 seconds Note There is on...

Страница 12: ...start delay between each station assigned to the same program During the delay no station will operate The delay can be set from 0 to 99 seconds You can set a different delay between stations assigne...

Страница 13: ...appears on the sprinkler see following paragraph no manual start is possible Even if the display shows the sprinkler with the blinking stream no irrigation can take place Important if the water budge...

Страница 14: ...s disappears Note In the shutdown mode the LED lamp on the front panel is red C SATELLITE MODE Your controller can operate as a satellite in the Tele Manager central control system To operate in the s...

Страница 15: ...to prevent it c There is a non blinking cross You cannot make an On Site modification No automatic watering will occur but you can manually start a station or cycle Only Tele Manager Software can modi...

Отзывы: