EZN850
53
4.7.4 Serial Communication
RS485 Setting
Camera ID: This entry is used to assign camera own ID code.
Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS485 port on the camera. There are six different speeds,
2400/4800/9600/19200/38400/57600. The default setting from the factory is 9600.
Protocol: Select protocol from EverFocus and Pelco-D. The default setting from the
factory is Pelco-D.
Data Bit: This field is the data bit at which you will be transferring. There are two
settings for this option: 8 or 7. The default is set to 8.
Stop Bit: This field is to set the stop bit for the RS485 connection. There are two
different stop bits, 1 or 2. The default is set to 1.
Parity: This field is to select the parity level at which you will be connected. You can
choose between None, Odd, or Even parity levels. Default is set to none.
Содержание NeVio EZN850
Страница 1: ...EZN850 User s Manual Copyright EverFocus Electronics Corp Release Dec 2009 Rev C ...
Страница 10: ...EZN850 10 ...