ES0812-31 

8-Port 10M/100M + 2-Port Giga uplink (1*TP+1*SFP)   
Desktop Web Smart PoE Switch 

 

                                                                                 

 

 

User’s Manual 

 
 
 
 
 

  

 

 
 
 
 
 
 
 

Copyright © EverFocus Electronics Corp, 

Release Date: September, 2013 

 

Notice: This content is subject to be changed without notice. 

Содержание ES0812-31

Страница 1: ... Port 10M 100M 2 Port Giga uplink 1 TP 1 SFP Desktop Web Smart PoE Switch User s Manual Copyright EverFocus Electronics Corp Release Date September 2013 Notice This content is subject to be changed without notice ...

Страница 2: ...verfocus Electronics Corporation Release Date September 2013 QuickTime is a registered trademark of the Apple Computer Inc Windows is a registered trademark of the Microsoft Corporation Linksys is a registered trademark of the Linksys Corporation D Link is a registered trademark of the D Link Corporation DynDNS is a registered trademark of the DynDNS org Corporation Other product and company names...

Страница 3: ...e will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect th...

Страница 4: ...on 12 4 2 1 1 System IP Configuration 12 4 2 1 2 System Status 14 4 2 1 3 Load Default Setting 15 4 2 1 4 Firmware Update 16 4 3 Port Management 18 4 3 1 Port Configuration 18 4 3 2 Port Mirroring 20 4 3 3 Bandwidth Control 20 4 3 4 Broadcast Storm Control 21 4 3 5 PoE 22 4 4 VLAN Setting 24 4 4 1 VLAN Mode 24 4 4 2 VLAN Member 25 4 4 3 Multi to 1 Setting 29 4 5 Per Port Counter 30 4 5 1 Port Coun...

Страница 5: ...P Filter 36 4 8 Spanning Tree 38 4 8 1 STP Bridge Settings 38 4 8 2 STP Port Settings 39 4 8 3 Loopback Detection Settings 40 4 9 Trunking 42 4 10 Backup Recovery 44 4 11 Miscellaneous 45 4 12 Logout 48 4 13 Q A 49 ...

Страница 6: ...e switch is designed for small or medium network environment to strengthen its network connection This product is compact 11 size making it ideal for Desktop users with limited space It also gives you the option of installing it in a 19 cabinet by rack mount kits or underneath a desk 1 2 Key Features Standard Standard IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX IEEE 802 ab 1000BaseT IEEE 802 3z 1000B...

Страница 7: ...ls Bandwidth Control for TX and RX Rate Broadcast Storm Control Broadcast Storm Control and Threshold Setting PoE Control PoE Enable Disable PoE Status Port Counter Statistic Monitor the port statistic VLAN Setting VLAN Mode Port based and Tag based VLAN Port Based VLAN Up to 10 ports Port Based VLAN Tag Based VLAN Up to 32 VLANs Available DID from 1 4094 QoS Setting Support High Low Priority Queu...

Страница 8: ...ACP Long Short Timeout time IGMP Snooping V1 V2 Basic Features Embedded HTTP web Management User name Password Authentication Configuration Configuration Backup Recovery TFTP Firmware upgradeable Secure Management LED LED Indicator System Power Per Port Link Act PoE Port Act Status Power Power Input 100 240V AC 50 60HZ PoE Power Output 802 3at compliant 30W Max per Port Power Consumption 130Watts ...

Страница 9: ...itch 4 1 3 Package Before you start to install this switch please verify your package that contains the following items One Switch One Power Cord One User Manual CD Optional Accessory 11 to 19 Rack mount kit ...

Страница 10: ...ch consists of 8 10 100Base TX RJ 45 ports 1 10 100 1000M RJ 45 and 1 Gigabit SFP uplink ports LED The LED Indicators are also located on the front panel They indicate the System and Port Status Load Default Push Button The button allows you to restore the configuration to default Rear Panel The 3 pronged power plug is placed at the rear panel of the switch right side shown as below LED Display Gi...

Страница 11: ... space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables power cord and allow air circulation The last use twisted pair cable to connect this switch to your PC then user could start to operate the switch AC Power Input Connect the attached power cord to the AC power input connector the available AC power input is range from ...

Страница 12: ...ect the transmit channel at each end to the receive channel at the opposite end 2 4 Hardware Restore Button The purpose of this button is to provide a method for the network administrator to restore all configurations to the default value To activate this function the user should follow the following procedures 1 Press the Load default button for 3 seconds until you see all the LED blinking 2 When...

Страница 13: ...talled on your network and that every PC on this network can access the switch via the web browser Verify that your network interface card NIC is operational and that your operating system supports TCP IP protocol Wire the switch power and connect your computer to the switch The switch default IP address is 192 168 2 1 The Switch and the connected PC should locate within the same IP Subnet Change ...

Страница 14: ...sword Default user name and password are both admin If you can t login the switch the following steps can help you to identify the problem 1 Switch to DOS command mode and type the ipconfig to check the NIC s setting Type the ping 192 168 2 1 to verify a normal response time 2 Check the security or Firewall settings high security level may limit the web access Check with the IT people 3 Try differ...

Страница 15: ...he procedure At the first open the web browser and go to 192 168 2 1 site then the user will see the login screen Key in the password to pass the authentication then clicks the OK The log in process is completed and comes out the sign Password successfully entered Log in ID admin Password admin Figure 1 1 Note It will show error message if you key in wrong user name or password Figure 1 2 ...

Страница 16: ...PoE Switch 11 Main Page Figure 1 3 ...

Страница 17: ...sername and Password in this page Figure 2 1 4 2 1 1 System IP Configuration This page shows system configuration including the current IP address Subnet Mask and Gateway Figure 2 2 User can configure the IP settings Subnet Mask Gateway as below IP Address Manually assign the IP address that the network is using The default IP is 192 168 2 1 ...

Страница 18: ... the switch will try get the IP Address from the DHCP server Click Update to update the new settings It will show update successfully then press Reboot button It will enter user login screen automatically Click DHCP Update you can see the warning message Note After changed to DHCP mode the switch must be restarted to get new IP address however since the switch only provide web management it is har...

Страница 19: ... hardware address assigned by manufacturer default Number of Ports Displays number of ports in the switch Comment Add character here for not System Version Displays the switch s firmware version Idle Time Security User can set the time security When user leave the computer for a moment the software will auto logout or back to the last display Click Update button to update the information The syste...

Страница 20: ...ribed as following The purpose of this button is to provide a method for the network administrator to restore all configurations to the default value To activate this function the user should follow the following procedures 1 Press the Load default button for 3 seconds until you see all the LED blinking 2 When LED starts blinking it means the CPU is executing the load default procedure You can rel...

Страница 21: ...the code of flash memory will be erased All functions will be detected except the firmware update itself If want proceed click Yes to continue If not please click Cancel Figure 2 6 The smart switch will erase the flash memory There is a self protection mechanism in the Boot Loader so the Boot Loader will keep intact Even though the power is turned off or the cable link fails during the firmware up...

Страница 22: ...ace right of the Browse command will display the file name you selected Press Update to continue the firmware upgrading process Figure 2 8 The below screen shows the Uploading process is starting Figure 2 9 After firmware correctly uploaded the web screen shows OK Type Continue to re login the switch Figure 2 10 Note The reboot is for software base instead of hardware base ...

Страница 23: ...figuration Function Tx Rx Ability Enable or Disable The default value is Enable Being set as Enable the port can Transmit and Receive packet without any problem After changed to Disable the selected ports can access the network any more Auto Negotiation Enable and Disable Being set as Enable the Speed Duplex mode Pause Backpressure TX Capability and Address Learning are negotiated automatically Wh...

Страница 24: ...ackpressure Flow Control for connection at speed of 10 100Mbps in Half duplex mode Addr Learning When the Auto Negotiation column is set as Disable users have to set this column as Enable or Disable Select Port No Select the port ports you want to apply to You can select one or multiple ports here Click Update to have the configuration take effect Current Status Displays the status of each ports T...

Страница 25: ...to choose what type of packet is to be monitored Rx indicates the Received Packets Tx indicates the Transmitted Packets Tx Rx indicates Both Transmit and Received Source Port The ports that the user wants to monitor All monitored port traffic will be copied to mirroring destination port Users can select multiple source ports by ticking the check boxes beneath the port number label to be monitored ...

Страница 26: ...Type 5 for both Tx and Rx Rate and select the High as speed base for port 1 and port 10 The actual rate for port 1 Fast Ethernet is 1280 for port 9 Gigabit Port is 10240 You could see the table is updated as below Figure 3 4 4 3 4 Broadcast Storm Control The switch implements a broadcast storm control mechanism Tick the check boxes to have them beginning to drop incoming broadcast packets if the r...

Страница 27: ...fic Threshold Type in the threshold in the range between 1 and 63 to limit the maximum byte counts which a port can send or receive in a period of time Enable Port Having ticked the boxes the port will stop transmitting or receiving data when their sending byte counts or receiving byte counts reach the defined threshold Example to change one time unit to pps The port 1 is 100M port The one time of...

Страница 28: ...igure 3 6 Port The port number Enable Enable PoE feature of the specific ports PSE Current The PSE Current Range Minimum Output Power The minimum output power of the port PoE Class The PoE class of the connected port ...

Страница 29: ...the same switch physically 4 4 1 VLAN Mode You may select the VLAN Mode of the switch Port based VLAN is for separating traffic only on this single switch There is no handover of network traffic within VLAN groups to other switches For the handover to other switches use Tag Based VLAN In VLAN Mode you can switch from Tag to Port Based VLAN Port Based VLAN is the default mode Figure 4 1 After havin...

Страница 30: ... packet received at the source port This is the default setting when starting VLAN configuration You should change to either Add or Remove Tag Remove Tag Remove tag means the 802 1Q tag of the outgoing packet of the selected port will not be sent Use this setting for your Network Connections to PCs Only packets of the VLAN Group the Port is member of will be sent 4 4 2 VLAN Member The ports need t...

Страница 31: ... then select or deselect the ports that are on the same VLAN group In this configuration mode you do not need to worry about defining VLAN groups and VLAN IDs VLAN Member in Tag Based Mode In Tag Based Mode you need to define and configure your VLAN groups Assign the VLAN ID select the VLAN member ports assign the PVID and check the configuration result ...

Страница 32: ...LAN member for this entry and then press this button to add a VLAN entry to the table The available range of VID is from 1 4094 Delete Select a VID in the table and then press this button to remove a VID entry from the table After deleted the VLAN and its member port setting is gone Update Modify the existing VLAN setting Select the VID the below settings will be displayed you can change the setti...

Страница 33: ...untagged the incoming packets will then be tagged with PVID within the switch and then follow the VID table to forward traffic Port VID Map This table shows the PVID of the ports VLAN Member Table This table shows the VID and its member ports Configuration Steps First add your VLAN Groups identified throughout your network by unique and constant numbers Start with IDs from 100 and up is often Star...

Страница 34: ...o 1 Setting Multi to 1 VLAN is used in CPE side of Ethernet to the Home and is exclusive to VLAN setting on VLAN Member Setting When VLAN member Setting is updated multi to 1 setting will be void and vice versa The disable port means the port which will be excluded in this setting All ports excluded in this setting are treated as the same VLAN group In a normal Tag Based VLAN network you will not ...

Страница 35: ...ed packet count Collision Count Transmit packet This category shows the packets outgoing from the switch and the count of collision Drop packet Receive packet This category shows the number of received valid packet and the number of dropped packet CRC packet Receive packet This category shows the received correct packet and received CRC error Once your see CRC error increasing here please notice t...

Страница 36: ...PoE Switch 31 Clear Press clear will clear all counters Refresh Press Refresh button will aggregate the number of the counter for all ports ...

Страница 37: ...fy such classes but they do not guarantee delivery as do quality of service QoS functions which are implemented in the network devices 4 6 1 Priority Mode There are three priority modes available to specify the priority of packets being serviced Those include First In First Out All High Before Low and Weight Round Robin Figure 6 1 First In First Out Packets are placed into the queue and serviced i...

Страница 38: ...ty A packet received by a high priority port is handled as a high priority packet VLAN Tag The switch follows the VLAN tag of the incoming packets to forward traffic VLAN Tag priority high priority 4 7 low priority 0 3 IP DS The switch follows the IP TOS Diff Serve of the incoming packets to forward traffic Ipv4 DS and Ipv6 TC high priority 10 18 26 34 46 48 56 low priority others 4 6 3 TCP UDP Po...

Страница 39: ...network administrator to assign the specific application to a priority queue F I F O The incoming packet will be forwarded in first in first out scheme Discard The incoming packet will be discarded at the source port High The incoming packet will be forwarded with the high priority Low The incoming packet will be forwarded with the Low priority ...

Страница 40: ... to one specific port Figure 7 1 MAC Address Type the target MAC address you want to bind for the specific port User can assign up to 3 MAC addresses to the port Select Port Select the port number and click Read button If you don t enter any MAC Address before the address is blank If you have entered any MAC address the field will display the MAC addresses your previously entered Binding Enable or...

Страница 41: ...ol will be either forwarded or dropped at secure WAN port as the figure shown below negative means the selected protocol will be dropped and other protocols will be forwarded positive means the selected protocol will be forwarded and other protocol will be dropped Protocol Select the pre defined known protocol or User_Define Protocol number Secure WAN Port The port number of the Secured WAN Port T...

Страница 42: ...PoE Switch 37 Click Update to have the configuration take effect ...

Страница 43: ...device with the highest priority becomes the STP root device However if all devices have the same priority the device with the lowest MAC address will then become the root device Number between 0 61440 in increments of 4096 Therefore there are 16 distinct values Hello Time Interval in seconds at which the root device transmits a configuration message BPDU frame Number between 1 10 default is 2 Max...

Страница 44: ...ormation of the STP domain 4 8 2 STP Port Settings The STP Port Setting page allows you to change the port priority and its path cost After STP RSTP is enabled the system automatically assigns the port priority and path cost to the prot Normally it is necessary to change the parameters however you may need to control the root switch or block port in some condition This page allows you to change th...

Страница 45: ...ith slower media Set the RSTP path cost on the port Number between 0 200000000 0 means auto generated path cost State Show the current port state includes Designated port Root port or Blocked port Status Show the current port status includes Forwarding Disable Blocking etc 4 8 3 Loopback Detection Settings In some condition the user may incorrectly connect the wrong port and lead the network loop ...

Страница 46: ... Loopback Detection function Auto Wake Up Once the Loopback Detection function is running the ports maybe be disabled to avoid the loop The Auto Wake Up allows you to activate the port after Time Interval passed Wake Up Time Interval Select the time interval here Click Submit to apply the settings ...

Страница 47: ...balancing is maintained whenever a link in a trunk is lost or returned to service This switch may use Source MAC Address or a combination of Source MAC Address and Destination MAC Address to be the selection for Trunk Hash Algorithm Traffic pattern on the network should be considered carefully before applying it When a proper hash algorithm is used traffic is kind of randomly decided to be transmi...

Страница 48: ...ame Operation Key This column allows you to type operation key Time Out This column allows you to select Long Time Out Time or Short Time Out Time The Long Time Out is around 30 seconds the Short Time Out is around 3 seconds however the link partner of other supplier may not use the same value The longer time then will be used Activity This column allows you to select Passive or Active mode Note I...

Страница 49: ...switch configuration The user can save configuration file to a specified file If the user wants to recover the original configuration which is saved at the specified path just enter the password and then press the upload button Finally the original configuration of the switch will be recovered Figure 10 1 ...

Страница 50: ...ts In some application for example the IPTV Multicast communication the multicast stream is continuously generating from the source port the client port may be congested because of the limited bandwidth or slow network processing ability Then the Pause frame of Flow Control will be generated once the packet buffer is full With the Output Queue Aging Time feature when a packet is stored at output q...

Страница 51: ...witch will by default flood multicast traffic to all ports in a broadcast domain Multicast can cause unnecessary load on host devices by requiring them to process packets they have not solicited The IGMP snooping is a feature that allows the switch to listen in on the IGMP conversation between hosts and routers By listening also known as snooping to these conversations the switch maintains a map o...

Страница 52: ...able VLAN Uplink Setting If VLAN uplink function is enabled and the destination port of an unicast packet is located at the next VLAN this packet will be forwarded to the uplink port Choose the Uplink Port X for the port ID The Uplink X will be the uplink port of its VLAN Note There is a functional conflict between VLAN striding and VLAN uplink Imagine what will happen if both VLAN striding and VL...

Страница 53: ... the switch you can click Logout to leave the configuration page The administrator has write access for all parameters governing the onboard agent User should therefore assign a new administrator password as soon as possible and store it in a safe place ...

Страница 54: ...l default Step 1 Turn on the Web Smart Switch Step 2 Press and hold the reset button continuously for 5 seconds and release the reset button Step 3 The switch will reboot for 20 seconds and the configuration of switch will back to the default setting Figure 12 1 Key in the user ID and the password to pass the authentication the user ID and the password are admin IP 192 168 2 1 ID admin Password ad...

Страница 55: ...V1 0 First Release Nov 15 2012 V1 1 Update latest product specification Update latest figure of web UI Add information of the Miscellaneous setting Jan 9 2013 V1 2 updated Optional Accessory 11 to 19 Rack mount Kit PoE Output voltage from 48V to 802 3at compliant Feb 8 2013 ...

Страница 56: ...1 3 5625 8189 www everfocus co jp info everfocus co jp EverFocus Europe UK Unit 12 Spitfire Business Park Hawker Road Croydon Surrey CR0 4WD UK TEL 44 20 8649 9757 44 845 430 9999 FAX 44 20 8649 9907 www everfocusuk co uk salesuk everfocus com EverFocus India Suite 803 Housefin Bhavan C 21 Bandra Kurla Complex Bandra East Mumbai 400051 India TEL 91 22 6128 8700 FAX 91 22 6128 8705 www everfocus in...