5.
Wire Connection
Connect the power supply cable (AC24V/DC12V), video output and
alarm output to the proper connectors shown as Figure 7.
The V. Phase adjustment screw is located on the termination board.
The vertical phase may require adjustment to synchronize the vertical
phase of the camera with other cameras in the system when it is to be used
in the line-lock sync mode. Make sure the vertical phase adjustment of
the camera does not match other cameras.
Note: The inner part of power plug is positive. The pigtail wire with the white
stripe is positive.
Termination Board
7
Micro Switch for Alarm trigger
Video
Alarm COM
GND
Alarm NO
Alarm NC
Power In
(+)
Power In
(-)
V. Phase Adjustment VR
Figure 7
7