Installation
9
4. Disconnect
after use
AFTER
EACH
USE,
disconnect power to the pump
using the following
procedure:
a)
Disconnect the vehicle battery ground wire.
b)
Disconnect the pump’s
black
wire from the
negative (-)
terminal of
the battery.
c)
Disconnect the pump’s
red
wire from the
positive (+)
terminal of the
battery.
d)
Reconnect the vehicle battery ground wire.
Note:
Skip steps (a) and (d) if battery is not in a vehicle.
WARNING:
Always disconnect in this sequence to avoid possible shock.
NOTE: It is important to disconnect power to the pump when not in use for
safety reasons. ALWAYS verify that the power has been disconnected
before adding chemicals or servicing.
A remote switch is recommended for temporarily shutting off the pump’s operation.
Call EverFlo Product Support at 1-800-864-1649 for more information.