EASY DECISION
A stainless steel cleaner can be applied which gives the cooktop an extra shine. Only apply after cleaning
with soapy water.
Avoid leaving acidic or alkaline substances on the cooktop.
Burners and enamelled components are only to be washed with soapy water & sponges. Do not use
abrasive cleaners on these components.
When cleaning burner components, please ensure that they are fully dry before re-placing on the cooktop
and before use.
Ensure that all components are placed back onto the cooktop correctly. Failure to do so can cause
problems with the burners igniting and functioning correctly. See diagrams on the following page for how
to put the burners back together.
WOK BURNER MAINTENACE & ASSEMBLY
When fitting the wok burner together, it is very important to check that the burner
flame distributor (F) and the cap (C) are correctly positioned (fig. 6). Failure to do
so can cause problems with ignition and also the way in which the burner
operates.
Check that the electrode (S) is always clean to ensure trouble-free sparking.
Check that the probe (T) is always clean to ensure correct operation of the safety
valves (for models with safety device).
The Wok burner must be correctly positioned (see fig.7). The burner rib must lock
into position on the assembly below. If positioned correctly, the burner will not
rotate (fig.8).
Then position the enamel cap A and the enamel ring B (fig.8).
The four holes around the outside of the crown must always be kept
clean.
When cleaning, remove the flame divider (fig.9) and use a cotton bud,
toothbrush, or a stiff wire brush to clean out any incrustations or dirt
from the four holes marked “H” (fig.10).
This procedure is necessary to ensure the burner functions correctly.
MAINTENANCE
Clean burner tops and trivets at least once a week, or after any spillage. Check injectors are not blocked
and the electrode and probe are clean.
Gas inlet pipes should be checked periodically for leakages (see section on leak testing) a minimum of every
12 months.
Lubrication of gas valves - This can only be performed by an authorised person. It may be required if the gas
tap become stiff and difficult to turn.
Fault
Possible cause (corrective action)
No spark / No ignition
of gas.
Power outage, appliance power turned off at isolation switch, fuse blown / tripped, no gas to the
appliance (check supplies). Spillage of liquid over burner (clean up spillage on burner
components). Burner not assembled correctly (Refer to assembly instruction manual).
Burner ignites but
flame goes out when
control knobs released.
Control knob not depressed down enough when igniting burner, control knob being released
from the ignition mode too early (try ignition again). Spillage of liquid over burner (clean up
spillage on burner components). Burner not assembled correctly (Refer to assembly instruction
manual). Faulty thermocouple (technician call out required call Service Centre).
Erratic / Abnormal
flames or noise when
operating the
appliance.
Burner not assembled correctly (Refer to assembly instructions). Spillage of liquid over burner
(Clean up spillage on burner components). Oversize cooking vessel being used on the appliance
(use smaller cooking vessels). Internal ignition of burner (Turn off gas and reignite burner). Wrong
gas type being used (check supply and data labels).