EASY DECISION
ELECTRICAL CONNECTIONS
LOCAL AUTHORITY REQUIREMENTS
Installation is only permitted by an authorized person, and carried out according to instructions
provided by the manufacturer. Incorrect installation might cause harm and damage which the
manufacturer accepts no responsibility.
INSTALLATION
This cooktop must be connected to a 220-240V 50Hz power supply. It is earthed via the cord.
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on
the appliance identification plate) must be checked for correspondence to the available mains supply
voltage, and the mains electric wiring should be capable of handling the hob’s power rating (also indicated
on the identification plate);
The switched fused spur outlet must be connected to a suitable earth wiring, in conformity to current safety
regulations.
This appliance must be wired into a 30A double pole switched fused spur outlet, having 3 mm contact
separation and placed in an easily accessible position adjacent to the appliance. It should not be located
above the appliance and no more than 1.25m away from it. The power supply cord must not touch against
any hot surfaces and must be placed so that its temperature does not exceed 75 °C at any point along its
length. Cable type: H05 RRF 3 core x 2.5 mm².
After having installed the appliance, the double pole switched fused spur outlet must always be in an
accessible position.
NOTE: For connections to the mains power supply, never use adapters, reductions or multiple power points
as these may overheat and catch fire.
The mains terminal block is located on the underside of the hob and the terminals are accessible by
removing the terminal block cover by removing the cover screw.
The cable connections must be in accordance with the
diagram located on the bottom of the cooktop.
The brass links must be positioned as marked in the
appropriate diagram and once established ALL terminal
screws must be tightened down firmly. If when the hob is first switched on, only two of the zones work, you
should recheck that the terminal screws are all fully tightened between the links. The cable can be looped if
necessary, but make sure that is not kinked or trapped when the hob is in position.
IMPORTANT: The appliance must NOT be connected to the mains supply by means of a 10A or 15A plug
and socket and installation is only permitted by an authorised person.
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement which can
only be installed by a qualified person. The mains supply cable should be replaced in accordance with the
following instructions:
Switch the appliance off at the control switch. Open the terminal block on the underside of the hob.
Unscrew the terminal screws fixing the cable. Replace the cable with one of the same length and in
accordance with the specification given above. The “green-yellow” earth wire must be connected to the
terminal marked. It must be about 10 mm longer than the live and neutral wires. The “blue” neutral wire
must be connected to the terminal marked with letter (N) - the live wire must be connected to the terminal
marked with letter (L).
The installation will require connection and modifications to the mains supply wiring system. This can only
be carried out by a qualified technician to the relevant local regulations.
The technician will also have to verify that the cross-section of the electric cables on the power point match
the appliance’s power rating.
5