background image

 

 

 

HOMEDEPOT.COM  

 

Please contact 1-877-297-6069 for further assistance. 

Pre-Installation  

PRODUCT DESCRIPTION 

               

                                                                                                                                             

*The weep hole prevents the pump from becoming 

“air-locked”, a condition which will not allow the pump to pump water. 

 
 
 

Installation 

 

Installing the basin  

 
 

 

□  Remove  the  eight  outer  bolts 

securing the cover to the basin and 
set  aside.  Take  the  cover  off  the 
basin.   

□  Remove  the  contents  from  the 

basin  and  remove  the  components 
shown  in  the  product  description 
above from their packaging.  

□  Excavate  a  hole  large  enough  to 

accommodate 

the 

basin 

(A), 

backfill material (1) and inlet piping 
(2). 

□  Add  4  –  6  in.  of  clean  sub-base 

material  or  concrete  (3)  to  the 
bottom of the hole. 

□  Assure  that  it  is  level,  compacted, 

and smooth. 

□  Place the basin (A) in the hole and 

ensure that it is level. 

Part          Description 

Basin (with pump and 
accessories inside) 

Gas-tight Cover w/Pipe Flanges 
and Cord Grommet 

Everbilt Model HDSS50           
1/2 HP Cast Iron Sewage Pump  

2 in. Discharge Pipe Assembly 
w/Weep Hole* 

2 in. Compression Fit Check 
Valve  

4 in. Snap-In Inlet Hub  

Reusable Seal 

Содержание THD1100

Страница 1: ...ce your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt Model THD1100 USE AND CARE GUIDE PRE PACKAGED SEWAGE BASIN SYSTEM WITH HEAVY DUTY 1 2 HP SEWAGE PUMP Questions problems missing parts Call Everbilt Customer Service 8 a m 7 p m EST Monday Friday and Saturday 9 a m 6 p m EST 1 877 297 6069 HOMEDEPOT COM ...

Страница 2: ...in water lf basement floor is wet do not walk on wet area until all power is turned off If shut off box is in basement call the electric company to shut off service to the house or call your local fire department for instructions Remove pump and repair or replace Failure to follow this warning can result in fatal electrical shock WARNING Extension cords may not deliver sufficient voltage to the pu...

Страница 3: ...d abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduced in size if the pump has been used in water temperatures above the advertised rating or water containing sand lime cement gravel or other abrasives if the product has been used to pump chemicals or hydrocarbons or if the label bearing the system model has been removed Your sole re...

Страница 4: ... type power cord and snap action float switch This pump operates automatically Ball bearings on motor shafts never need lubrication TYPICAL INSTALLATION TOOLS REQUIRED Flathead screwdriver 7 16 Nut Driver or Wrench Hacksaw or PVC Cutter Tape measure PVC primer PCV cement Safety goggles MATERIALS REQUIRED NOT INCLUDED Before using this pump ensure you have the following items 2 in PVC Schedule 40 P...

Страница 5: ...ts shown in the product description above from their packaging Excavate a hole large enough to accommodate the basin A backfill material 1 and inlet piping 2 Add 4 6 in of clean sub base material or concrete 3 to the bottom of the hole Assure that it is level compacted and smooth Place the basin A in the hole and ensure that it is level Part Description A Basin with pump and accessories inside B G...

Страница 6: ...ly into the pump s discharge opening Make sure the weep hole is pointing away from the float Position the pump in the bottom of the basin so that influent from the inlet pipe will not fall directly on the pump s float switch Make sure the reusable cover seal is in place on the top edge of the basin lined up with the basin bolt holes Place the basin cover loosely on the basin Remove the cord gromme...

Страница 7: ... discharge Hand tighten the fittings to ensure a watertight seal It is a good idea to install a shutoff valve in the discharge line between check valve and the sewer if service to the system is required in the future 5 Attaching the vent connection Install a 2 in PVC Schedule 40 threaded male adaptor not included into the vent flange Use thread seal tape to seal the threads Connect a 2 in PVC Sche...

Страница 8: ...8 Pump Performance Chart Care and Cleaning ...

Страница 9: ...ets may cause low voltage at the motor This could cause blown fuses tripping of motor overload or a burned out motor WARNING Before servicing a pump always shut off the main breaker and unplug the pump Under flooded conditions make sure you are not standing in water and that you are wearing insulated protective sole shoes Contact your electric company or a qualified licensed electrician for discon...

Страница 10: ...Questions problems missing parts Call Everbilt Customer Service 8 a m 7 p m EST Monday Friday and Saturday 9 a m 6 p m EST 1 877 297 6069 HOMEDEPOT COM Retain this manual for future use ...

Отзывы: