Pre-Installation (continued) 

PLANNING INSTALLATION 

Inspect the pump and motor for delivery damage. Report any damage immediately to the shipping carrier or to your dealer. 

The well driller should thoroughly develop the well (that is, pump out all fine sand and foreign matter) before the pump is installed. See the 
Initial Start-Up section of this document. 

Pump performance is based on pumping clear, cold, liquid water with no entrained air. Warranty is void in the following conditions: 

 

If the pump has pumped excessive sand – excessive sand can cause premature wear to pump. 

 

If water is corrosive. 

 

If entrained gas or air are present in the water being pumped – these can reduce flow and cause cavitation which can damage pump. 

 

If pump has been operated with discharge valve closed – severe internal damage will result. 

Install the pump at least 15 to 20 ft. (4.5 to 6 M) below the lowest water level reached with the pump running (lowest draw-down water 
level), and at least 5 ft. (1.5M) above the bottom of the well. 

GROUNDING THE PUMP 

 

WARNING: 

Risk of electric shock. Can shock, burn or kill. Permanently ground the pump, motor, and control box before connecting the 

power supply to the motor.

 

 

Ground the pump and motor in accordance with the local codes and ordinances. Use a copper ground wire at least as large as wires 
carrying current to motor. 

The motor is supplied with a copper ground wire. Splice this ground wire to a copper conductor that matches motor wire size specified in 
Wiring Connections for wire splicing instructions. 

Permanently ground the pump, motor and control box before connecting the power cable to power supply. Connect the ground wire to the 
approved ground first and then connect to the equipment being installed. 

Do not ground to a gas supply line. 

 

WARNING: 

Risk of electric shock and fire. Can shock, burn or kill. If using a drop wire larger than No. 10 (5.5 mm

2

) (for example, No. 8 

(8.4mm

2

) wire) between the pump and control box, run wire to a separate junction box. Connect the junction box to the control box with a 

No. 10 (5.5 mm

2

) or smaller wire (depending on amp rating of the pump). For more information, contact your local code officials.

 

 

Wiring Connections 

 

 

All wiring must meet National Electrical Code or Canadian Electrical Code and local code requirements. Use only copper wire when making 
connections to pump and control box. 

To avoid over-heating wires and excessive voltage drop at the motor, ensure the wire size is at least as large as the size listed in the 
following tables for your horsepower pump and length of wire run. 

 

NOTICE: 

When built-in overheating protection is not provided, use with an approved overload equipped motor control that matches motor input in full 

load amps. Select or adjust overload element(s) in accordance with control instructions. When built-in overheating protection is provided, use with an 
approved motor control that matches motor input in full load amperes. 

 

Recommended  Fusing Data - 60 Hz., Single Phase, 3 Wire 

Submersible Pump Motors 

Recommended  Fusing Data  - 60 Hz., Single Phase 2 Wire 

Submersible Pump Motors 

HP 
HP

Volts Fuse 

Size 

Stand 

Dual 

C.B. 

1/2 230 

15 

10 

15 

3/4 230 

25 

15 

20 

1 230 

30 

15 

25 

 

HP 
Volts

Volts
Volts

Fuse Size
Stand

Dual 

C.B. 

1/2

230

15

10

10 

3/4

230

15

10

15 

1

230

20

15

20

 

 
 

Содержание EFSUB10-122HD

Страница 1: ...rovement needs Thank you for choosing Everbilt Item 1001 092 349 1001 092 255 1001 092 261 1001 092 264 1001 092 483 1001 092 258 1001 092 273 Model EFSUB5 122HD EFSUB5 123HD EFSUB7 122HD EFSUB7 123HD...

Страница 2: ...cause cracking in plastics Use only Teflon tape when sealing joints in plastic pipe or connecting pipe to thermoplastic pumps WARNING California Proposition 65 Warning This product and related accesso...

Страница 3: ...ranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to r...

Страница 4: ...ches the voltage of the well NUMBER OF PUMP WIRES AND CONTROL BOXES 4 in pumps are offered in either 2 wire or 3 wire the number of wires running from the pump motor 2 wire motors have 3 wires running...

Страница 5: ...ons for wire splicing instructions Permanently ground the pump motor and control box before connecting the power cable to power supply Connect the ground wire to the approved ground first and then con...

Страница 6: ...Wire Cable 60 Hz Wire Size HP Volt Wire Size AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371...

Страница 7: ...olor coding when connecting control box Yellow to Y Red to R Black to B Single phase 2 wire connections 2 wire pumps have two power supply wire Black and one ground wire Green Control box is not requi...

Страница 8: ...1 1 2 in 38 mm on each side of the joint Make four passes with the tape When finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the w...

Страница 9: ...or body and tighten by hand for a strong waterproof splice POWER SUPPLY WIRE INSTALLATION 1 To test submersible momentarily no more than 30 seconds connect it to the proper power supply Power supply f...

Страница 10: ...low the procedure below when starting the pump for the first time NEVER start a pump with the discharge completely open unless you have done this procedure first 1 Connect a pipe elbow a short length...

Страница 11: ...ill void the warranty Protect the pump and entire piping system including pressure tank from freezing PRE CHARGED PRESSURE TANK HOOKUP This diagram shows a typical submersible installation with a pre...

Страница 12: ...kPa Control box 3 wire models only Electrical Disconnect Box Pre Charged Tank Ground Level Conduit or Sleeve Plastic Pipe Adapter Power Cable Nylon Tape Cable Splices Centering Guide Plastic Pipe Ada...

Страница 13: ...box Check the control box wiring diagram against the incoming power hookup Check drop cable color coding Reconnect the drop cable so the cable color code matches the motor lead color code There is a b...

Страница 14: ...n the well while the pump is running and compare to the pump depth setting Lower the pump further into the well but at least 5 ft 1 6M above the bottom of the well Throttle the pump discharge until th...

Страница 15: ...HOMEDEPOT COM 15 This page intentionally left blank Please contact 1 844 883 1872 for further assistance...

Страница 16: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM Retain this manual for future use...

Страница 17: ...oblemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente de Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM GRACIAS Apreciamos la...

Страница 18: ...n tape para sellar las juntas en tuber a pl stica o tuber a de conexi n a las bombas termopl sticas ADVERTENCIA Advertencia de la Propuesta 65 de California Este producto contiene sustancias qu micas...

Страница 19: ...ginal y la etiqueta de informaci n de la garant a La elegibilidad est basada en la fecha de compra del producto original y no en la fecha del reemplazo bajo la garant a La garant a est limitada a la r...

Страница 20: ...voltaje de la bomba que seleccione coincida con el voltaje del pozo N MERO DE CABLES Y CAJAS DE CONTROL DE LA BOMBA Las bombas de 4 pulg se ofrecen con 2 cables o 3 cables el n mero de cables que sal...

Страница 21: ...necte el cable de tierra a la tierra aprobada primero y luego conecte al equipo que se est instalando No haga la conexi n a tierra a una l nea de suministro de gas ADVERTENCIA Riesgo de choque el ctri...

Страница 22: ...del cable HP Voltio Calibre del cable AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 0 75 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371 59...

Страница 23: ...de 2 cables Las bombas de 2 cables tiene un cable de alimentaci n negro y un cable de tierra verde No se requiere caja de control Esta es informaci n de conexi n correcta para motores de 2 cables de 1...

Страница 24: ...ta Cubre el cable unas 1 1 2 pulg 38 mm en cada lado de la junta Haga cuatro vueltas con la cinta Cuando haya terminado debe tener cuatro capas de cinta envueltas apretadamente alrededor del cable Pre...

Страница 25: ...E ALIMENTACI N 1 Para probar la bomba sumergible con ctela moment neamente no m s de 30 segundos a la fuente de alimentaci n apropiada La frecuencia y voltaje de la fuente de alimentaci n deben coinci...

Страница 26: ...rranque la bomba por primera vez NUNCA arranque una bomba con la descarga completamente abierta a menos que haya hecho primero este procedimiento 1 Conecte un codo de tuber a una corta longitud de tub...

Страница 27: ...de presi n contra el congelamiento ACOPLAMIENTO DEL TANQUE DE PRESI N PRECARGADO Este diagrama muestra una instalaci n sumergible t pica con una instalaci n de tanque precargado AVISO Los motores de...

Страница 28: ...conexi n el ctrica Pre cargado el tanque El nivel del suelo Conducto o manga Adaptador de tuber a de pl stico Cable de alimentaci n Cinta de nylon Empalmes de cables Gu a de centrado Adaptador de tube...

Страница 29: ...codificaci n por color del cable de ca da Vuelva a conectar el cable de ca da de modo que el c digo de color del cable coincida con el c digo de color del conductor del motor Hay un cable roto en la c...

Страница 30: ...mientras la bomba est funcionando y compare con el ajuste de profundidad de la bomba Baje m s la bomba al pozo pero al menos 5 pies 1 6 m sobre el fondo del pozo Estrangule la descarga de la bomba has...

Страница 31: ...HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional esta p gina est en blanco 15...

Страница 32: ...8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM Conserve este manual para uso futuro Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente...

Отзывы: