background image

 

 

Table of Contents

 

 

 

Table of Contents .......................................................... 2

 

Performance .................................................................. 2

 

Safety Information ......................................................... 2

 

Warranty ......................................................................... 3

 

Pre-Installation .............................................................. 4 

 

 

Installation ..................................................................... 6

 

Operation ....................................................................... 6

 

Airlock ............................................................................ 7

 

Care and Cleaning ........................................................ 7

 

Troubleshooting ............................................................ 9 

 

 

SKU 

HP 

GPH of Water @ Total Feet Of Lift 

Max. Lift 

0 ft. 

5 ft. 

10 ft. 

15 ft. 

20 ft. 

1001627571 

1/8 

1800 

1560 

1320 

960 

240 

21 ft. 

 

Safety Information

 

 

 

 

DANGER

Do not pump flammable or explosive liquids such as 

oil, gasoline, kerosene, ethanol, etc. Do not use in the presence 

of flammable or explosive vapors. Using this pump with or near 
flammable liquids can cause an explosion or fire, resulting in 

property damage, serious personal injury, and/or death.

 

 

 

WARNING

Wear safety goggles at all times when working 

with pumps. 

 

 

 

WARNING

This unit is designed only for use on 115 volts 

(single phase), 60 Hz, and is equipped with an approved 

3-conductor cord and 3-prong grounded plug. Do not remove 
the ground pin under any circumstances. The 3-prong plug must 

be directly inserted into a properly installed and grounded 
3-prong, grounding-type receptacle. Do not use this pump with 

a 2-prong wall outlet. Replace the 2-prong outlet with a properly 
grounded 3-prong receptacle installed in accordance with the 

National Electrical Code and local codes and ordinances. All 
wiring should be performed by a qualified electrician.

 

 

 

 

DANGER

:

 ALWAYS disconnect the power to the pump before 

servicing.

 

 

 

 

DANGER

Do not touch the motor housing during operation. 

The motor is designed to operate at high temperatures. Do not 

disassemble the motor housing.

 

 

 

 

 

 

WARNING

Protect the electrical cord from sharp objects, hot 

surfaces, oil, and chemicals. Avoid kinking the cord. Do not use 
damaged or worn cords.

 

 

DANGER

Do not handle the pump or pump motor with wet 

hands or when standing on a wet or damp surface, or in water 
before disconnect the power.

 

 

 

 

WARNING

Failure to comply with the instruction and 

designed operation of this unit may void the warranty. 
ATTEMPTING TO USE ADAMAGED PUMP can result in property 

damage, serious personal injury, and/or death. 

 

 

 

WARNING

Release all pressure and drain all water from the 

system before servicing any component.

 

 

 

 

 

 

WARNING

Secure the discharge line before starting the 

pump. An unsecured discharge line will whip, possibly causing 

personal injury, and/or property damage.

 

 

WARNING

Ensure that the electrical circuit to the pump is 

protected by a 10 Amp fuse or circuit breaker.

 

 

 

 

 

 

WARNING

Extension cords may not deliver sufficient voltage 

to the pump motor. Extension cords present a life threatening 
safety hazard if the insulation becomes damaged or the 

connection ends fall into water. The use of an extension cord to 
power this pump is not permitted.

 

.

 

CAUTION

Do not lift the pump by the power cord.

 

 

 
 

Performance

 

 

Содержание 1001627571

Страница 1: ...designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt SKU 1001627571 Model UT08804 USE AND CARE GUID...

Страница 2: ...ld be performed by a qualified electrician DANGER ALWAYS disconnect the power to the pump before servicing DANGER Do not touch the motor housing during operation The motor is designed to operate at hi...

Страница 3: ...hen it stops If the water level is not over 2 in the pump will not start The manufacturer warrants the products to be free from defects in materials and workmanship for a period of two years from date...

Страница 4: ...tested or approved for use in swimming pools or in salt water marine areas This pump is not designed to function as a permanently installed sump pump It is also not engineered to be run continuously...

Страница 5: ...llation continued PACKAGE CONTENTS NOTE The adaptor is not shown to scale Part Description A Pump B 3 4 in garden hose adaptor C Base SPECIFICATIONS Power supply 115V 60 HZ 10 Amp Circuit Liquid Temp...

Страница 6: ...e pump to the base C Securely attach the hose kit not included to the adaptor B Attach the adaptor B to the pump outlet Install the pump to the base C Attach a garden hose with a 3 4 in garden hose th...

Страница 7: ...the power cord restarting the pump CAUTION This hole is for anti airlock purposes Leakage of air or water is NORMAL and NECESSARY DO NOT REMOVE OR BLOCK THIS HOLE Care and Cleaning CAUTION Always use...

Страница 8: ...ilter base 2 Pull the cap up along the pump housing 3 Clean the debris and contamination around the sensor probes 4 To clean the pump clogged with debris Remove the screws 4 and take out the volute 3...

Страница 9: ...er 3 Check for damaged wiring or moisture 4 Secure the plug 5 Clean the plug prongs 6 Replace the pump 7 Allow the water level to rise to 2 in or more 8 Remove the blockage The pump is unable to pump...

Страница 10: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM...

Страница 11: ...s para mejorar su hogar Vis tenos en nuestra p gina de internet para ver la l nea completa de productos disponibles para las mejoras de su hogar Gracias porescoger a Everbilt SKU 1001627571 Modelo UT0...

Страница 12: ...nes deben ser hechas por un electricista profesional PELIGRO SIEMPRE desconecte la bomba antes de hacerle mantenimiento PELIGRO No toque el motor mientras est funcionando Este producto est dise ado pa...

Страница 13: ...continuar su funci n hasta que el nivel de agua baje a 3 8 pg Y luego parar Si el nivel de agua no est sobre 2 pg la bomba no prender El fabricante garantiza los productos de cualquier defecto de mat...

Страница 14: ...ido probada o aprobada para usar en piscinas o en zonas de agua salada Esta bomba tampoco ha sido fabricada para operar continuamente como una fuente o una cascada de agua No use donde el agua se reci...

Страница 15: ...DEL PAQUETE NOTA Adaptador mostrado no a escala Parte Descripci n A Bomba B Adaptador de manguera jard n de 3 4 pg C Base Especificaciones Voltaje 115V 60 HZ Circuito de 15 Amperios Rango de Temperat...

Страница 16: ...ra menos presi n se pierde o m s eficiente se vuelve la bomba en cuanto a la velocidad de flujo Conecte el adaptador B a la salida de la bomba Instalar la bomba a la base C Sujete la manguera de jard...

Страница 17: ...trictamente relacionados con el anti airlock La de aire y agua es normal y necesario NO QUITE EL HUECO NI LO OBSTRUYA Cuidado Y Mantenimiento CAUTELA Siempre use la manilla para levantar la bomba Nunc...

Страница 18: ...la tapa hacia arriba a lo largo del cuerpo de la bomba 3 Limpie los desechos y la contaminaci n alrededor de las sondas del sensor 4 Para limpiar la bomba obstruida con mugre Quite los tornillos 4 y s...

Страница 19: ...no haya cables da ados ni humedad 4 Asegure el enchufe 5 Limpie las puntas del enchufe 6 Reemplace la bomba 7 Deje que el agua suba a 2 pg o m s 8 Quite la obstrucci n La bomba no puede bombear agua...

Страница 20: ...Preguntas problemas piezas que faltan Antes de devolverla a la tienda llame a Servicio al Cliente de 8 00 AM a 6 00 pm EST de Lunes a Viernes 1 844 241 5521 HOMEDEPOT COM...

Отзывы: