Ever Sharp Technology ES2020 Скачать руководство пользователя страница 4

永匯豐科技有限公司

 

                   

Ever Sharp Technology, Inc 

 

 

INNOVATION TECHNOLOGY ADVANCES WORKFLOW

    

http://www.eversharp.com.tw

 

7. Troubleshooting

 

Problem Possible 

Cause 

Correction 

Indicator or 

display does not 

light 

• no power input 

• PCB main board damage 

• check power cord connection 

• turn on power 

• replace new PCB main board 

Cannot dispense 

• foot pedal not plugged in properly 

• defective foot pedal 

• foot pedal port broken or loosen 

• defective Solenoid Valve 

 

• check connection 

• foot pedal needs to be repaired or replaced

• remove the cover and check for broken or 

loosen 

• replace the valve and make sure you use 

the appropriate piston and do not turn the 

vacuum too large 

System will not 

pressurize 

• Insufficient air pressure 

• air pressure connector not plugged in 

• regulator defective 

• increase air supply pressure 

• check connection 

• replace pressure regulator 

System will not 

pull vacuum 

• vacuum setting is too low 

• barrel piston not appropriate 

• adhesive too watery or full 

• increase vacuum volume 

• replace with appropriate piston 

• replace with different adhesive and fill only 

3/4 full in the barrel 

Inconsistent 

dispensing 

• air bubbles in adhesive 

• dispensing needle not appropriate 

• dispensing needle clogged 

• decrease vacuum setting and de-bubble 

the adhesive before filling 

• replace with different type of needle 

• replace needle 

 

8. Limited warranty

 

Ever Sharp warrants this product to the original purchaser for a period of one year from date of purchase to be free from 

material and workmanship defects but not normal wear-and-tear, abuse and faulty installation. Defective product or 

subassembly and components under warranty will be repaired or replaced (at Ever Sharp option) free of charge. Customer 

with defective product under warranty must contact the nearest Ever Sharp office or distributor to secure a return 

authorization prior to shipping the product to the assigned Ever Sharp authorized service center. For nearest Ever Sharp 

office or distributor contact information, please visit 

www.eversharp.com.tw

 or contact our stuff. Ever Sharp reserves the 

right to make engineering product changes without notice. 

Содержание ES2020

Страница 1: ...ssor line b Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system c Fill the dispensing barrel with adhesive up to 2 3 full and adapt with barrel adapter Connect the adapter to the front of the system d If you are using Finger Switch please stick the switch on the dispensing barrel e Connect the Power Cord on the back of the system and switch the power on Ple...

Страница 2: ...h precise dispensing you will need to use low pressure dispenser 0 30 psi 3 Control Setting 1 Pressure Indicator Display the currently air pressure in the system 2 Pressure Regulator Adjust the air pressure in the system increase with clockwise and decrease with counter clockwise 3 Barrel Adapter Port Connect with barrel adapter press down and rotate to adapt 4 Vacuum Knob Adjust the suck back pre...

Страница 3: ...is designed and built to be relatively maintenance free To assure trouble free operation the following recommendations should be followed a Make certain air supply is clean and dry b Avoid turning barrels upside down or laying barrel so that material may run through air line to internal components c Avoid turning the vacuum to large and cause the generation of bubbles in the material or the materi...

Страница 4: ...increase vacuum volume replace with appropriate piston replace with different adhesive and fill only 3 4 full in the barrel Inconsistent dispensing air bubbles in adhesive dispensing needle not appropriate dispensing needle clogged decrease vacuum setting and de bubble the adhesive before filling replace with different type of needle replace needle 8 Limited warranty Ever Sharp warrants this produ...

Отзывы: