2.5
Main Panel
Line
Bypasses the plug-in. When engaged, the signal is passed
through the plug-in; when off, the plug-in is bypassed.
Bounce
Mimics the effect of the tape reel servo motors bouncing when
you release them. At 0% there’s no bounce, at 100% there is
maximum bounce. The bounce occurs when the control signal
changes direction. So when using the LFO, the bounce will oc-
cur at either end of the oscillator, when it transitions between
ascending and descending.
Depth
Controls the mix of wet and dry signals. At 0% the output is
solely the delayed signal. At 100% the output is the sum of the
delayed signal and the input. At
−
100% the output is the sum
of the delayed signal and the
inverted
input.
Oscillator Rate
Controls the rate of the LFO between 0.01 Hz and 20 Hz when
un-synced, and between 16 bars and 64th note when Sync is
activated.
Manual Knob
Provides manual control of the flanging. 0% corresponds to
setting the bucket brigades to their longest delay times, while
100% sets them to their shortest.
Feedback
Controls the feedback of the flanger output. 0% sends none of
the output back to the input to the bucket brigades, and 100%
sends the maximum amount of output back to the input of the
bucket brigades.
Feedback Inv.
Located under the Feedback knob, this switch inverts the signal
that is fed back to the input.