background image

 

 

www.event-lighting.com.au 

Green 

000-255 

Blue 

000-255 

White 

000-255 

Auto Program 

Auto Color 

  

Auto Fade 

  

Language 

English 

  

Chinese 

  

Display 

Normal 

  

Reverse 

Flip 180° 

Backlight 

On 

Always on 

30s 

Off after 30 seconds of inactivity 

Fixture test 

Red 

  

Green 

  

Blue 

  

White 

  

Factory Settings 

No 

  

Yes 

Reset to factory settings 

System Info 

RDM UID 

  

Version 

Software Version 

DMX Channel 

Current DMX channel mode 

Run time 

Total usage time 

User time 

Time since power on 

Temperature 

Current temperature 

 

 

 

Содержание DELUGE27X15

Страница 1: ...erves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item Version 1 1 September 2022 ...

Страница 2: ...tion where excessive heat or water beyond the IP65 specification may affect it Do not operate this device if the housing lenses or cables appear damaged Do not connect this device to a dimmer or rheostat ONLY connect this device to a grounded and protected circuit ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient tem...

Страница 3: ...3 www event lighting com au Dimensions Lux Chart ...

Страница 4: ...Description DMX Address 001 512 Set DMX address DMX Channel Mode 4 Channel Mode 4 channel DMX mode 7 Channel Mode 7 channels DMX mode 8 Channel Mode 8 channels DMX mode Dimmer Mode Dimmer Mode 1 Dimmer Mode 2 Dimmer Mode 3 Dimmer Curve Dimmer Curve 1 Dimmer Curve 2 Dimmer Curve 3 Dimmer Curve 4 LED Frequency 600 Hz 1200 Hz 2000 Hz 4000 Hz 6000 Hz 25 kHz Manual Colour Red 000 255 ...

Страница 5: ...ormal Reverse Flip 180 Backlight On Always on 30s Off after 30 seconds of inactivity Fixture test Red Green Blue White Factory Settings No Yes Reset to factory settings System Info RDM UID Version Software Version DMX Channel Current DMX channel mode Run time Total usage time User time Time since power on Temperature Current temperature ...

Страница 6: ... several fixtures need to be independently controlled we just simply address first fixture at 1 and second fixture at 8 third one at 15 etc If multiple fixtures have the same DMX address they will behave synchronically Display will flash when no DMX signal is received Mode Channel Min DMX Max DMX 4 Ch 7 Ch 8 Ch Function Description 1 1 Dimmer 0 255 Dimmer 0 100 2 2 Strobe 0 255 Strobe slow to fast...

Страница 7: ...nput Voltage 100 240V AC 50 60 Hz Power Consumption 350 W Connection True1 in out Control Protocol DMX512 Operation Modes DMX auto manual sound active master slave DMX Channels 7 14 42 Interface 3 pin XLR in out Display 4 button 2 4 inch LCD control panel Cooling Fanless Housing Materials Aluminium Finishing Matte black IP rating IP65 Dimensions 465 81 240 mm Net Weight 6 6 kg Warranty Please refe...