pwm
FUnctiOn
Heating characteristic (mode 1)
When the PWM signal is switched off, the pump runs at maximum speed .
this ensures that the system can function in an emergency, even if the controller
is defective or the connection cable is broken .
as the PWM signal rises, the speed of the pump falls .
the following characteristic shows how the pump reacts to the various PWM signal
levels . to prevent the system from cycling, the characteristic has a hysteresis in
zone d .
MAX
speed
Min
pWM (%)
led 1 flashes
A = Maximum speed
B = variable speed Min – MAX
c = Minimum speed
d = Hysteresis on – off
e = stand-by mode off