9
pump and fan –
delay compressor parameter
. The electric heater operates above ECO-PLUS
temperature, in Party mode and in case of failure.
Attention:
The heater is not installed in the device. It is an optional external component, which can
be controlled by the heat pump controller.
5. Main menu
5.1 Party
When Party mode is activated, the heat pump tank reaches the set temperature as soon as possible.
In this mode, all available heat sources connected to the controller operate simultaneously.
5.2 Legionella
When this function is activated, the boiler heats up to 70°C (factory setting) and maintains this
temperature for a specified period of time, then returns to normal operation. Any changes to the
settings for this function are only possible in the service menu.
5.3 Detail screen
The detailed screen shows the temperatures measured by the sensors and the status of the pressure
switches.