Step 8
Use the gas orifi ce tool to remove the
LP orifi ce from side burner valve.
Step 9
Make sure all control knobs are OFF,
then remove all the control knobs.
Tighten screw on each control valve.
Note:
This screw regulates the low
fl ame setting for natural gas. After
replacing knobs you will notice
the knobs will stop at the “MED”
setting on the dial. This is the
correct low setting for natural gas.
Do not try to turn the knob to “LO”
setting.
Step 10
Carefully replace all burners, making
sure burner openings slide over valve
nozzles. Attach each main burner
using studs and cotter pins that were
set aside in previous step. Attach side
burner using wing nut and reattach wire
clip to side burner that were set aside in
previous step. Reattach any electrodes
that were detached in previous steps.
Reattach all control knobs.
Replace heat tents,cooking grates and
warming rack and side burner grate.
8
LP GAS
ORIFICE
ORIFICE
TOOL
Do not remove
this part