6
Method B:
1. Drill 4 holes of Ø 6mm at the bottom of the hanging cupboard.
2. Put the outlet to the cooker hood, then install the cooker hood on the bottom of the
cupboard, tighten the cooker hood with enclosed 4 screws.
3. Install the adjusted board on the bottom of the hood in order to keep out the gap
between hood back and cupboard. See pic 3.
Pic 3
Noice: There are 2 methods for ventilation, including ' horizontal ventilation' and '
vertical ventilation'. Please pay attention to the ventilation method when installation.
Horizontal ventilation: See pic 4A, please use the cover to seal the outlet on the top,
then the air can be vented from back.
Vertical ventilation: See pic 4B, please use the cover to seal the outlet on the back,
then the air can be vented from top.
Pic 4
Air ventilation setting
Outdoor air ventilation: Turn the adjuster to outdoor position (pic 5A), install the outlet,
turn on the cooker hood, then the air will be vented from the outside outlet.
Indoor air ventilation: Turn the adjuster to indoor position (pic 5B), install the outlet
cover, turn on the cooker hood, then the air can be vented from the inside outlet.
Pic 5