between 1 - 1.2m long. The hose should not be subjected to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length. Unions compatible with the hose fittings must be used
and connections tested for gas leaks.
.The fixed consumer piping outlet should be at approximately the same
height as the cooker connection point, pointing downwards and approximately 150mm to the side of the
cooker. The hose should be clear of the floor when the cooker is in the installed position. Fix one end of the
chain on the screw next to the gas inlet connection and the other end should be anchored to the floor/wall so
that the chain prevents strain on the hose connections when he cooker is pulled forward.
The appliance is factory set for Natural gas. The test point pressure should be adjusted to
with the
Triple ring burner operating at maximum.
The appliance is set up to operate with the gas specified on the gas type label placed on the back of the
appliance.
To perform these operations the qualified installer will follow the indications given in the "Adaptation to the
various types of gas" section. For safer operation make sure that the supply pressure respects the values given
in the "Table of burner and injector characteristics".
If installing for use with
gas, ensure a gas regulator suitable for a supply pressure of
is part of the
gas tank supply and the test point pressure is adjusted to
.
Once the appliance has been installed, make sure that the gas pipe is neither squashed or damaged by moving
parts.
Before Leaving - Check all connections for gas leaks with soap and water. DO NOT use a naked flame for
detecting leaks. Ignite all burners both individually and separately to ensure correct operation of gas valves,
burners and ignition. Turn gas taps to low flame position and observe stability of the flame for each burner
individually and separately. When satisfied with the operation of the cooker, please instruct the user on the
correct method of operation. In case the appliance fails to operate correctly after all checks have been carried
out, refer to the authorised service provider in your area.
Adaptation to different types of gas
To adapt the appliance to a gas different from that
for which it was set up (see gas type label inside
the warming compartment door) proceed as follows:
remove the grids
remove the burners caps and burner heads
with a 7 mm socket spanner unscrew and remove the injectors.
replace the injectors with those supplied corresponding to the
gas available (see burner and injector characteristics Table)
replace the various parts proceeding in reverse.
When converting from Natural Gas to
ensure that theNG regulator is removed and replaced with the Test
Point Assembly. A gas regulator suitable for a supply pressure of should be part of the gas tank supply and the
test point pressure should be adjusted to
Setting the minimum flame
The flame on the small output is regulated by the factory.
When the injectors have been replaced or there are special
mains pressure conditions, it may be necessary to regulate
the minimum flame again. The operations necessary to set
the minimum flame are as following:
light the burner ;
turn the knob to the minimum position ;
take out the knob (and gasket if there is one) ;
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit (e.g. a drawer)and does not pass through any space
susceptible of becoming congested
20mbar
LPG
29mbar
29mbar
When converting from Universal LPG to Natural Gas ensure that the LPG test point is removed and replaced
with the CE Approved NG Regulator supplied in this kit. The test point pressure must be adjusted to
20mbar with the largest burner operating on maximum flame.
When converting from Natural Gas to Universal LPG ensure that the NG regulator is removed and replaced
with the Test Point Assembly supplied in this kit. An CE Approved gas regulator suitablefor a supply pressure
of 29mbar should be part of the gas tank supply and the test point pressure must be adjusted to 29mbar.
LPG
the pressure according to the data plate.
l
l
l
l
l
l
l
l
7
If installing for use with
gas, ensure a gas regulator suitable for a supply pressure of
is part of the
gas tank supply and the test point pressure is adjusted to
.
TG
8mbar
8mbar
Содержание ANDER 90
Страница 1: ...Instruction Manual Freestanding Cooker ANDER 90...
Страница 10: ......
Страница 15: ...3 14...