ELECTRICAL CONNECTION
The appliance is fitted with an approved 15 Amp flexible cord and plug which must be connected to a
correctly earthed socket outlet. The manufacturer is not liable for any direct or indirect damage caused by
faulty installation or connection. It is therefore necessary that all installation and connection operations are
carried out by qualified personnel complying with the local and general regulations in force.
The wire section on the cable must not be less
Than1.5mm (3
×
1.5cable).Use only the special
cables available at our service centers.
CONNECTION OF THE FEEDING CABLE TO THE MAINS
Connect the feeding cable to a plug suitable for the load indicated on the rating plate of the product. In case of
a direct connection to the mains (cable without plug), it is necessary to insert a suitable omnipolar switch
before the appliance, with minimum opening between contacts of 3 mm (the grounding wire should not be
interrupted by the switch).
Before connecting to the mains, make sure that:
The electrical counter, the safety valve, the feeding line and the socket are ade
quate towithstand the maximum load required(see rating plate).
The supply system is regularly grounded, according to the regulations in force.
The socket or the omnipolar switch can easily be reached after the installation
of the oven.
After carrying out the connection to the mains, check that the supplying cable
does not come into contact with parts subject to heating.
Never use reductions, shunts, adaptors which can cause overheating or burning.
The manufacturer is not liable for any direct or indirect damage caused by faulty installation or connection. It
is therefore necessary that all installation and connection operations are carried out by qualified personnel
complying with the local and general regulations in force.
Electrical features
Oven light
2×25W
2200W
1800W
2900W
2×1250W
Upper heating element
Bottom heating element
Grill heating element
Circular heating element
This appliance shall be installed only by authorised persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations, municipal building codes, electrical wiring
regulations, local water supply regulations.
Ventilation
In general, the appliance should have adequate ventilation for complete combustion of gas, proper flueing
and to maintain temperature of immediate surroundings within safe limits.
Combustible Surfaces
Any adjoining wall surface situated within 200mm from the edge of any hob burner must be a suitable non-
combustible material for a height of 150mm for the entire length of the hob. Any combustible construction
above the hotplate must be at least 600mm above the top of the burner and no construction shall be within
450mm above the top of the burner. Zero clearance is permitted on side and rear adjoining surfaces below the
hob.
Gas connection
The appliance must be connected to the gas supply or the cylinder according to the specifications of the
standards and after checking that it is adjusted for the type of gas available.
The gas connection is male 1/2
"
BSP and is situated 55mm from the right and 560mm from the floor.
There are two ways to carry out
the connection to the main gas line:
A. The Cooker can be connected with the cuprum material . Loosen the tie-in down and connect one terminal
of the pipe with the gas elbow
It's
necessity of changing the flexible tube whenthe national conditions require it.