background image

EVCO S.p.A. 

 

Vcolor

 | Hardware manual ver. 1.0 | Code 144VCOE104 

page 31 of 38 

8

 

SIGNALS 

8.1

 

Signals 

The following tables shows the meaning of the LED of the device. 

LED colour 

Meaning 

green 

LED power supply device 

if it is lit, the device will be powered 

green 

LED run 

if it is lit, the application software will be compiled and running in release modality 

if it flashes slowly, the application software will be compiled and running in debug modality 

red 

LED error 

if it is lit, an error will be arisen 

red 

LED CAN transmission 

if it is lit, the device will be configured to communicate via CANBUS with another device but 

the CAN communication will not have been set up 

if  it  flashes  slowly,  the  CANBUS  communication  will  have  been  set  up  but  it  will  not  be 

completely correct 

if it flashes quickly, the CANBUS communication will have been set up and will be correct 

if it is out, no CANBUS communication will be running 

red 

LED CAN reception 

if it is lit, the device will be configured to communicate via CANBUS with another device but 

the CAN communication will not have been set up 

if  it  flashes  slowly,  the  CANBUS  communication  will  have  been  set  up  but  it  will  not  be 

completely correct 

if it flashes quickly, the CANBUS communication will have been set up and will be correct 

if it is out, no CANBUS communication will be running 

 

The LED are located at the back of the devices; look at paragraph 4.2 “Description of the back”. 

 

 

Содержание Vcolor EPV4CBR

Страница 1: ...EVCO S p A Vcolor Hardware manual ver 1 0 Code 144VCOE104 page 1 of 38 Vcolor Programmable remote user interfaces with color touch screen TFT graphic display Hardware manual ENGLISH Code 144VCOE104...

Страница 2: ...use of the device and follow all recommendations keep this document with the device for future consultation Only use the device in the way described in this document do not use the same as a safety de...

Страница 3: ...wiring diagram 13 4 DESCRITPION 14 4 1 Description of the front 14 4 2 Description of the back 15 5 FIRST USE 16 5 1 First use 16 6 PRELIMINARY INFORMATION 17 6 1 Switching on off the device 17 6 2 A...

Страница 4: ...s an IP40 protection rating IP65 in case of panel mounting with gasket 0027000007 to order separately for easy cleaning They can work both as browser of programmable controllers browsers and in comman...

Страница 5: ...0 x 240 pixel color touch screen TFT graphic display protection rating IP40 IP65 in case of panel mounting with gasket 0027000007 to order separately Connections EPV4CBR screw removable terminal block...

Страница 6: ...94 104 8 4 125 B 70 0 2 755 70 0 2 755 70 8 2 787 C 22 0 0 866 23 0 0 905 24 0 0 944 D 40 8 1 606 41 8 1 645 42 8 1 685 2 2 Panel mounting The following drawing shows the installation of the devices T...

Страница 7: ...built in mounting of the devices in box like 506e BTicino It is necessary to install the box vertically Through the frontal plates CPVP EVCO to order separately or the plates belonging to the series L...

Страница 8: ...on for installation make sure the working conditions of the device operating temperature operating humidity etc are in the limits indicated look at chapter 10 TECHNICAL DATA do not install the device...

Страница 9: ...Power supply Power supply device 24 VAC DC not isolated If the device is powered in direct current it will be necessary to respect the polarity of the power supply voltage Terminal Meaning 4 negative...

Страница 10: ...Through the USB port it is possible to make one of the following operations upload and download the application software through the development environment UNI PRO 3 or through a USB flash drive deb...

Страница 11: ...h CANBUS communication protocol it is necessary to plug in the line termination of the first and of the last element of the network To plug in the line termination position micro switch 2 on position...

Страница 12: ...EVCO S p A Vcolor Hardware manual ver 1 0 Code 144VCOE104 page 12 of 38 3 6 Example of wiring diagram The following drawing shows an example of wiring diagram of the devices...

Страница 13: ...y voltage working electrical frequency and working electrical power of the device they must correspond with the local power supply look at chapter 10 TECHNICAL DATA disconnect the local power supply b...

Страница 14: ...following drawing shows the aspect of the front of the devices The following table shows the meaning of the parts of the front of the devices PART MEANING 1 area HOME 2 area ESCAPE 3 area LEFT 4 area...

Страница 15: ...ng of the parts of the back of the devices PART MEANING 1 RS 485 communication port 2 dip switch to plug in the line termination of the RS 485 network with MODBUS communication protocol plug in the li...

Страница 16: ...e with the procedure shown in paragraph 7 4 Setting the configuration parameters of the menu Networks The following table shows the meaning of the main configuration parameters the parameters are list...

Страница 17: ...power supply 6 2 Access to the menu Info Diagnostic and Debug To gain access to the menu Info Diagnostic and Debug operate as follows 1 Switch on the device and show the sensitive areas look at parag...

Страница 18: ...h 6 1 Switching on off the device 2 Press and release the area USER the display will show the menu Network Status CAN 3 Press and release the area ENTER the display will show the menu V COLOR PROG 4 P...

Страница 19: ...ing the configuration parameters of the menu Parameters To gain access to the procedure operate as follows 1 Switch on the device and show the sensitive areas look at paragraph 6 1 Switching on off th...

Страница 20: ...show the submenu of the menu Networks 6 Press and release the area DOWN to select the submenu for example to select the submenu UART 7 Press and release the area ENTER the display will show the windo...

Страница 21: ...u of the menu Backup Restore 9 Press and release the area DOWN to select the submenu for example the submenu Backup Memory Select the submenu USB Key to make the upload from a USB key in this case it...

Страница 22: ...R the display will show the window Input Password 6 Press and release again the area ENTER 7 Press and release the area DOWN to set 19 8 Press and release the area ENTER the display will show the subm...

Страница 23: ...ected in step 9 14 Press and release the area ENTER it will be started the download of the configuration parameters The download takes typically a few seconds if the operation is not completed succesf...

Страница 24: ...raph 7 4 Setting the configuration parameters of the menu Networks According to the factory settings the CAN address of a controller is 1 in this case it is necessary to set parameter Network Node to...

Страница 25: ...n read only mode date and time of the last compiling of the application project 7 7 2 Configuration parameters of the menu Languages The following table shows the meaning of the configuration paramete...

Страница 26: ...ind of back light OFF the back light will always be off ON the back light will always be on TIME the back light will be on the time you have set with parameter Backlight Timeout from the last operatio...

Страница 27: ...CAN node address or of the device Master YES the device always works as master Baud Auto baud rate of the CAN communication 20K 20 000 baud 50K 50 000 baud 125K 125 000 baud 500K 500 000 baud Auto the...

Страница 28: ...Cnt Tx Err parameter available in read only mode reserved Cnt Rx Err parameter available in read only mode reserved Cnt Stuff parameter available in read only mode reserved Cnt Form parameter availabl...

Страница 29: ...d 38400 38 400 baud 57600 57 600 baud Bit Stop 1 bit number of stop bit of the MODBUS communication 1 bit 1 bit 2 bit 2 bit Timeout 2 240 s 10 time out of the local MODBUS communication or of the devi...

Страница 30: ...n by zero or for NaN KEY PAR parameter available in read only mode result of the upload and the download of the application software parameters or of the configuration parameters through the USB key O...

Страница 31: ...but the CAN communication will not have been set up if it flashes slowly the CANBUS communication will have been set up but it will not be completely correct if it flashes quickly the CANBUS communic...

Страница 32: ...2 0 m long the cable 0810500020 is 0 5 m long 9 2 Frontal plates CPVP 9 2 1 Preliminary information Through the plates it is possible to integrate the devices both in residential and commercial envir...

Страница 33: ...Vcolor Hardware manual ver 1 0 Code 144VCOE104 page 33 of 38 9 4 Gasket 0027000007 9 4 1 Preliminary information Through the gasket it is possible to guarantee an IP65 protection rating in case of pan...

Страница 34: ...inal blocks power supply RS 485 MODBUS port and CAN CANBUS port USB connector type A USB port The maximum length of the connecting cables are the following power supply 10 m 32 8 ft RS 485 MODBUS port...

Страница 35: ...upply must galvanically be isolated by those of the other elements of the RS 485 network with MODBUS communication protocol or the CAN network with CANBUS communication protocol Rated impulse voltage...

Страница 36: ...EVCO S p A Vcolor Hardware manual ver 1 0 Code 144VCOE104 page 36 of 38...

Страница 37: ...to EVCO EVCO does not take any responsibility about possible mistakes related The customer OEM installer or final user takes all responsibilities about the configuration of the device EVCO does not t...

Страница 38: ...EVCO S p A Vcolor Hardware manual ver 1 0 Code 144VCOE104 page 38 of 38 EVCO S p A Via Feltre 81 32036 Sedico Belluno ITALY Phone 39 0437 8422 Fax 39 0437 83648 info evco it www evco it...

Отзывы: