DIMENSIONS AND INSTALLATION
Control module dimensions and installation
The dimensions are expressed in mm (in); installation is envisioned on a flat surface, with shims.
(11)
the device memorises the defrosting interval count every 30 minutes; the setting of parameter d0 has effect from the conclusion of the previous defrosting interval (or the activation
of defrosting in manual mode)
(12)
the display restores normal operation when, on conclusion of evaporator fan standstill, the cabinet temperature or CPT temperature drops below that which has blocked the display
(or if a temperature alarm occurs)
(13)
if parameter P3 is set at 0 or 2, the device will function as if parameter d8 were set at 0
(14)
if when defrosting is activated, the operating duration of the compressor is less than the time established with parameter d5, the compressor will remain on for the amount of time
necessary to complete defrosting.
(15)
if parameter d8 is set at 3, the device will operate as if the parameter as been set at 0 and defrosting will be activated when the device has been on totally for the time established
with parameter d26
(16)
if parameter P3 is set at 0, the device will function as if parameter A0 were set at 0 but it will not store the alarm
(17)
during defrosting and dripping and when the evaporator fan is stopped, the temperature alarms are absent, provided that these were signalled after the activation of defrosting
(18)
during activation of the door microswitch input, the maximum temperature alarm is absent, provided the alarm was signaled after the activation of the input
(19)
parameters F13 and F14 have effect when the compressor is off
(20)
parameters F13 and F14 have effect when the compressor is on
(21)
if parameter P3 is set at 0, the device will function as if parameter F0 were set at 2
(22)
parameters F13 and F14 have effect when the evaporator temperature is below the temperature established with parameter F1
(23)
parameters F13 and F14 have effect when the compressor is on and the temperature of the evaporator is below the temperature established with parameter F1
(24)
evaporator fan activity is the following:
- if the temperature of the cabinet of the temperature detected by the inlet air probe is below the work set point, the fan will be switched off
- if the temperature of the cabinet or the temperature detected by the inlet air probe is between the work set point and “ work set point + F20”, the fan will be switched on at
a speed proportional to “cabinet temperature or the temperature detected by the inlet air probe - work set point”; the speed calculation formula is the following: Speed
= {[(cabinet temperature or temperature detected by the inlet air probe) - (work set point)] : F20} x 100
- if the temperature of the cabinet of the temperature detected by the inlet air probe is above the “work set point + F20”, the fan will be switched on at max. speed
(25)
if parameter P4 is set at 0, 2 or 3 the condenser fan will function in parallel with the compressor
(26)
the condenser fan is off when the temperature of the condenser drops below the temperature established with parameter F11 on condition that the compressor is off
(27)
the minimum variation of the evaporator fan speed is 10% of the maximum speed
(28)
if the parameter i0 and parameter i5 are set at the same value, the effect will be caused by the activation of at least one of the inputs (until both inputs are deactivated)
(29)
the compressor is switched off 10 sec after the activation of the input; if the input is activated during defrosting or when the evaporator fan is deactivated, the activation will not
have any effect on the compressor
(30)
the device stores the alarm once the time established in parameter i2 has expired; if parameter i2 is set at -1, the device will not store the alarm
(31)
make sure that the time established with parameter i7 is less than that established with parameter i9
(32)
to avoid damaging the unit connected to the instrument, set the parameter setting when the device is switched off
(33)
if parameter u2 is set at 0, switching off the device may cause the cabinet light and/or the auxiliary output to switch off (the next time the instrument is switched on the unit
connected will remain switched off); if parameter u2 is set at 1, switching off the device will not cause the cabinet light or the auxiliary output to switch off (the next time the
instrument is switched on the unit connected will remain switched on).
(34)
the heating elements are switched on when the temperature of the cabinet or the CPY temperature drops below the “work set-point + u7” and are switched off when the
temperature rises above the “work set-point + u7 + 2 °C/°F”.