12
Option 2:
230 V 1-phase with neutral
For 1-phase use of a Wye-connected secondary, only
a single phase (L1) and neutral must be connected.
This phase voltage must measure 230 V between line
and neutral.
Warning:
In this configuration, the charging station
operates only from a single phase (L1). Do not
connect the remaining phases L2 and L3.
Option 3:
230 V 1-phase without neutral
In this configuration (without a neutral and 230 V
from line to line), connect any two lines (L1, L2 or L3)
to the L1 and neutral positions on the terminal block
of the charging station.
Note:
In case you are not sure about the available
connection type at the service panel, consult a
qualified electrician.
L1
L2
L3
N
G
230 V
230 V
L1
L2
L3
N
G
230 V
2. Install
wall dock
EN