Rigging and

Assembly Instructions

ESW4 CLOSED CIRCUIT COOLERS

Visit 

EVAPCO’s

Website at: 

evapco.com

EVAPCO...

S

PECIALISTS IN

H

EAT

T

RANSFER

P

RODUCTS AND

S

ERVICES

.

EVAPCO Products are Manufactured Wordwide

Bulletin ESW419RIG

  EVAPCO, Inc. — World Headquarters & Research/Development Center

P.O. Box 1300 • Westminster, MD 21158  USA

410-756-2600 p  • [email protected] • evapco.com

EVAPCO, Inc.

World Headquarters

P.O. Box 1300

Westminster, MD 21158 USA

410-756-2600 p | 410-756-6450 f

[email protected]

Asia/Pacific

EVAPCO Asia/Pacific Headquarters

1159 Luoning Road

Baoshan Industrial Zone

Shanghai 200949, P.R. China

(86) 21-6687-7786 p  |  (86) 21-6687-7008 f

[email protected]

Europe

EVAPCO Europe BVBA

European Headquarters

Heersterveldweg 19

Industrieterrein Oost

3700 Tongeren, Belgium

(32) 12-395029 p  |  (32) 12-238527 f

[email protected]

EVAPCO East

5151 Allendale Lane

Taneytown, MD 21787  USA

410-756-2600 p | 410-756-6450 f

[email protected]

EVAPCO East

Key Building

Taneytown, MD  USA 

410-756-2600 p 

[email protected]

EVAPCO Midwest

Greenup, IL  USA 

217-923-3431 p

[email protected]

EVAPCO West

Madera, CA  USA

559-673-2207 p 

[email protected]

EVAPCO Iowa

Lake View, IA  USA

712-657-3223 p

EVAPCO Iowa

Sales & Engineering

Medford, MN  USA

507-446-8005 p

[email protected]

EVAPCO Newton

Newton, IL  USA

618-783-3433 p 

[email protected]

EVAPCOLD

Greenup, IL  USA 

217-923-3431 p

[email protected] 

EVAPCO-BLCT Dry Cooling, Inc. 

Bridgewater, NJ 08807  USA 

908-379-2665 p

[email protected]

EVAPCO-BLCT Dry Cooling, Inc.

Littleton, CO 80127  USA 

908-379-2665 p

[email protected]

EVAPCO Power México S. de R.L. de C.V.

Calle Iglesia No. 2, Torre E

Tizapan San Ángel, Del. Álvaro Obregón

Ciudad de México, D.F. México 01090

+52 (55) 8421-9260 p

[email protected]

Refrigeration Vessels & Systems Corporation

A wholly owned subsidiary of EVAPCO, Inc.

Bryan, TX USA

979-778-0095 p 

[email protected]

EvapTech, Inc.

A wholly owned subsidiary of EVAPCO, Inc.

Edwardsville, KS USA

913-322-5165 p 

[email protected]

Tower Components, Inc.

A wholly owned subsidiary of EVAPCO, Inc.

Ramseur, NC USA

336-824-2102 p 

[email protected]

EVAPCO Alcoil, Inc.

A wholly owned subsidiary of EVAPCO, Inc.

York, PA USA

717-347-7500 p

[email protected]

EVAPCO Europe, S.r.l.

Milan, Italy

(39) 02-939-9041 p

[email protected]

EVAPCO Europe, S.r.l.

Sondrio, Italy

EVAPCO Europe GmbH

Meerbusch, Germany

(49) 2159 6956 18 p

[email protected]

EVAPCO Air Solutions

A wholly owned subsidiary of EVAPCO, Inc.

Aabybro, Denmark 

(45) 9824 4999 p

[email protected]

EVAPCO Air Solutions GmbH

Garbsen, Germany

(49) 5137 93875-0 p

[email protected]

Evap Egypt Engineering Industries Co.

A licensed manufacturer of EVAPCO, Inc.

Nasr City, Cairo, Egypt

2 02 24022866/2 02 24044997 p

[email protected] / [email protected]

EVAPCO Middle East DMCC

Dubai, United Arab Emirates

+971 4 448 7242 p

[email protected]

EVAPCO S.A. (Pty.) Ltd.

A licensed manufacturer of EVAPCO, Inc.

Isando 1600, Republic of South Africa

(27) 11-392-6630 p

[email protected]

EVAPCO (Shanghai) Refrigeration Equipment Co., Ltd.

Baoshan Industrial Zone Shanghai, P.R. China 

(86) 21-6687-7786 p 

[email protected]

Beijing EVAPCO Refrigeration Equipment Co., Ltd.

Huairou District Beijing, P.R. China 

010-6166-7238 p 

[email protected]

EVAPCO Air Cooling Systems (Jiaxing) Company, Ltd. 

Building 10, 1133 Taoyuan Road,

Jiaxing, Zhejiang, China

(86) 573 83119379 p

[email protected]

EVAPCO Australia (Pty.) Ltd.

Riverstone NSW 2765, Australia

(61) 2 9627-3322 p 

[email protected]

EvapTech Asia Pacific Sdn. Bhd

A wholly owned subsidiary of EvapTech, Inc.

Puchong, Selangor, Malaysia

(60-3) 8070-7255 p  

[email protected]

North America

South America

EVAPCO Brasil 

Equipamentos Industriais Ltda.

Al. Vênus, 151 – CEP: 13347-659

Indaiatuba –São Paulo – Brasil

(55+11) 5681-2000 p

[email protected]

Fan Technology Resources

Cruz das Almas – Indaiatuba

São Paulo, Brasil 13308-200

55 (11) 4025-1670 p

[email protected]

Содержание ESW4

Страница 1: ...Bryan TX USA 979 778 0095 p rvs rvscorp com EvapTech Inc A wholly owned subsidiary of EVAPCO Inc Edwardsville KS USA 913 322 5165 p marketing evaptech com Tower Components Inc A wholly owned subsidiar...

Страница 2: ...electrical connections These items must be flexibly attached to the Evapco unit so as not to transmit additional loads to the equipment as a result of seismic or wind forces Structural Steel Support E...

Страница 3: ...e strain on the lifting devices See Table 2 for the minimum H dimension Bolt the bottom section to the steel support before rigging the top section of the unit The unit lifting devices should not be u...

Страница 4: ...the supporting steel and bolted in place the top flanges should be wiped down to remove any dirt or moisture Sealer tape should be placed over the mounting hole centerline on the side flanges along th...

Страница 5: ...r exists and for final positioning of the section For extended lifts safety slings should be provided under the section as described on page 6 2 OVERLAPPING LAYERS OF SEALER TAPE ON THE ENDS 1 LAYER O...

Страница 6: ...s to assure proper alignment lower the top section down onto the bottom section Place nuts and bolts in all four corner bolt holes Then continue to install the rest of the nuts and bolts working from...

Страница 7: ...section separate from the casing section the center of gravity of the fan section is heavily biased towards the location of the fan motor and major drive components In order to avoid lifting the fan...

Страница 8: ...match markings on each section i e A1 of bottom section should match up with A1 of top section Lower the upper section to within several inches of the bottom section making sure the two sections do no...

Страница 9: ...s supported from underneath by an X shaped support frame Set the support frame across the top of the discharge cylinder See Figure 13 and fasten to cylinder with 3 8 10mm bolts 3 Place the fan screen...

Страница 10: ...it for belt installation 7 Install Powerband belt K Figure 15 around fan sheave and motor sheave Tighten belt by adjusting nuts on J bolts Do not over tighten the belts The center of the belt should d...

Страница 11: ...a heater a low water cutout switch and a thermostat The heater is installed at the factory The low water cutout switch is shipped loose in the rigging box and will need to be screwed into the screw ti...

Страница 12: ...ing bolts A from the ladder mounting channels B on pan and casing sections 2 Loosen but do not remove the ladder bracket and assembly bolts C 3 Slide the ladder bracket assembly D over the ladder moun...

Страница 13: ...9 6 216 3 57 1 7 6 1 2 66 0 0 7 12 0 7 5 127 9 3 2 1 7 21 17 7KLV GRFXPHQW LV WKH SURSHUW RI YDSFR QF W VKRXOG QRW EH FRSLHG RU GLVFORVHG ZLWKRXW SULRU ZULWWHQ DXWKRUL DWLRQ 6 127 6 3 7 250 5 7 1 127...

Страница 14: ...installed on the discharge side of the pump and connected to a convenient drain In either case the bleed off valve should be fully open Strainer Check the strainers if applicable in the basin section...

Страница 15: ...tional arrows are placed on the side of the fan cylinder Maintenance Once the installation is complete and the unit is turned on it is important that it be properly maintained Maintenance is not diffi...

Страница 16: ...Water Level Control Probes Mounted in PVC standpipe Electronic Water Level Control PVC Standpipe Strapped Inside Unit Basin Shipping Location is Unit and Accessory Dependent External Service Platform...

Отзывы: