EVAPCO ATC-DC Series Скачать руководство пользователя страница 11

11

ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler

Assembly of Sloped Ladders

When sloped ladders are supplied with a unit, they are shipped
in the basin of the unit. One sloped ladder will be provided for
each cell. Assembly is identical for each cell.

See Figures 26 & 27 for end and side view ladder arrangement.

Sloped ladders are attached at a minimum of three points. Taller
units will be attached at four points. At each point of attachment,
the ladder will be fitted with a ladder bracket assembly. The
ladder bracket assembly looks like a metal box and is shown in
detail (component #4) in Figure 25 below. The upper two
assembly brackets will be rigidly mounted to the ladder and are
not adjustable. These two bracket define the slope of the ladder.
The lower brackets are adjustable.

To install the ladder assembly, follow the steps outlined below
which refer to Figure 25:

1.  Remove the ladder bracket mounting bolts (1) from the

ladder mounting channels (2) on pan and casing sections.

2.  Loosen, but do not remove, the ladder bracket and

assembly bolts (3).

3.  Slide the ladder bracket assembly (4) over the ladder

mounting channels (2) located on the pan and casing
sections. Do not remove the ladder bracket assembly (4)
from the ladder.

4.  Align the bolt holes and reinstall the ladder bracket

mounting bolts (1) through the ladder bracket assembly and
the ladder mounting channels (2).

5.  Tighten all bolts.

6.  Tighten the adjusting screw (5) in the adjustable mounting

bracket where applicable.

NOTE: Upper Section of Unit Must Be Properly Oriented
with Respect to Lower Section. All Mounting Brackets Must
be on Same Side of Unit. Refer to Certified Print For Proper
Orientation.

LADDER MOUNTING

CHANNEL (2)

ADJUSTING SCREW

(5)

(WHEN APPLICABLE)

LADDER

BRACKET

ASSEMBLY

(4)

LADDER

BRACKET

ASSEMBLY

BOLTS

LADDER BRACKET

MOUNTING BOLTS

(1)

Figure 25

- Detail of Ladder, Ladder Bracket Assembly and

Mounting Channel

Figure 26 

- End View of Ladder Assembly

Figure 27

- Side View of Ladder Assembly

Содержание ATC-DC Series

Страница 1: ...Inc A wholly owned subsidiary of EVAPCO Inc 8331 Nieman Road Lenexa KS 66214 USA Phone 913 322 5165 Fax 913 322 5166 E mail marketing evaptech com Tower Components Inc A wholly owned subsidiary of EV...

Страница 2: ...The International Building Code IBC is a comprehensive set of regulations addressing the structural design and installation requirements for building systems including HVAC and industrial refrigeratio...

Страница 3: ...nels and splash guards to keep water from exiting between the cells The equalizer flume is factory installed on one section for field connection to the other It is important to connect the equalizer f...

Страница 4: ...er Joining Multi Cell Units Basin Sections 17 20 24 Wide Models 12 to 40 Long On 17 20 and 24 wide models the equalizer flume is located on the sides of adjoining basin sections This flume is shipped...

Страница 5: ...the mating end with the smaller hole Stainless steel units will use 5 16 stainless steel nuts bolts and washers See Figure 9 11 Place the vertical splash guard in the bend of the vertical supports Att...

Страница 6: ...BOLTS SPREADER BEAM H Figure 14 Four Point Lift Fan Section Four lifting ears are provided in the lower corners of most coil fan sections for lifting into final position Some fan sections will have a...

Страница 7: ...f the unit Refer to Tables 1 and 2 for minimum H dimensions The preferred method for extended lifts is to use slings under the unit See Figure 16 Spreader bars should always be used between the cables...

Страница 8: ...sist with alignment Figure 17 Mating Upper Section to Basin Section Section 17 20 and 24 Wide Models Before assembling the coil section to the basin section remove any loose parts shipped in the pan W...

Страница 9: ...to Coil Basin Section 17 20 and 24 Wide Models Before assembling the fan section to the basin section wipe the flanges on the bottom of the coil fan section Check to see that the motor access doors ar...

Страница 10: ...SCREEN RODS FAN SCREEN ROD 1 2 BOLTS FLATWASHER LOCKWASHER FAN CYLINDER HEX NUTS WIRE CLIP Mounting Fan Screens 10 12 Wide by 14 through 20 Long Models 10 12 Wide by 28 through 40 Long Models 20 24 Wi...

Страница 11: ...move the ladder bracket mounting bolts 1 from the ladder mounting channels 2 on pan and casing sections 2 Loosen but do not remove the ladder bracket and assembly bolts 3 3 Slide the ladder bracket as...

Страница 12: ...rization SCALE 1 ALL 1 4 HOLES SHOULD BE 11 32 2 USE STAINLESS STEEL N C SET UP SHEET F F DETAIL E DETAIL B DETAIL A DETAIL C SHIP THIS DRAWING WITH UNIT CONNECTION PLATE CONNECTION PLATE SECURE DECK...

Страница 13: ...the side flanges although none are required on the end flanges NOTE Do not use U bolts to lift the discharge hood damper section when attached to another part of the equipment Always lift the hood Fi...

Страница 14: ...sing of unit for belt installation 7 Install Powerband belt K Figure 32 around fan sheave and motor sheave Tighten belt by adjusting nuts on J bolts Do not over tighten the belts The center of the bel...

Страница 15: ...nders of all models Check and tighten all bolts Float Valve Adjustment The float valve is pre set at the factory however adjustment should be checked after rigging The float valve should be adjusted s...

Страница 16: ...218B to 305B 77 3I to 77 6K 8 5x9 0 14 4 2 246B to 369B 89 3I to 89 6L 8 5x10 5 0 16 4 2 358B to 409B 102 3J to 102 6L 8 5x12 0 18 5 2 385B to 473B 119 3J to 119 6M 8 5x14 0 22 5 2 486B to 630B 153 3I...

Страница 17: ...Electronic Water Level Control PVC Standpipe Strapped Inside Unit Basin Shipping Location is Unit and Accessory Dependent External Service Platform with Ladder If Space is Available Strapped Inside U...

Страница 18: ...18 ATC DC Condenser eco ATWB H Closed Circuit Cooler Notes...

Страница 19: ...19 ATC DC Condenser eco ATWB H Closed Circuit Cooler Notes...

Страница 20: ...EVAPCO Inc P O Box 1300 Westminster MD 21158 USA PHONE 410 756 2600 FAX 410 756 6450 E MAIL marketing evapco com 2014 EVAPCO Inc Printed on recycled paper using soy based ink...

Отзывы: