6. Error Codes

The error codes are depicted by a number of flashes by the error light in a sequence every 

four seconds .

Code

Reason / Solution

ERR1 or ERR2 

(On Display 

instead on 

temperature) 

Faulty temperature probe 

•  Please call Evakool for closest service centre .

1 Flash 

Low Voltage

•  Please check the source voltage to ensure it is above the cut out . Try 

lowering the voltage cut out setting to LO .

•  The vehicle cabling may be inadequate/unsuitable, please refer to 

cable specifications table for correct cable thickness (page 5) .

•  Try on a different power source .

2 Flashes 

Fan or compressor running issue 

•  Fan is drawing too many Amps (Over 1 Amp) –Replace Fan .
•  The compressor is drawing too many amps (Over 12 Amps) .
•  Possible Electronic Box or compressor fault – contact Evakool or 

Service Agent .

3 Flashes 

The compressor speed is too low 

•  Reduce products / items inside unit .
•  Move unit to a lower ambient temperature .
•  Clean vents / ensure clear air flow over compressor .

4 Flashes 

Ambient Temperature too high 

•  Clean vents / ensure clear air flow .
•  Fan Fault – Replace fan .

5 Flashes

Thermal Cut-Out of Electronic Unit

•  If the refrigeration system has been too heavily overloaded .
•  Ambient temperature is too high .

TRAVELMATE

 XTREME

Содержание TMX35

Страница 1: ...INSTRUCTION MANUAL FOR MODELS TMX35 TMX50 TMX65 TMX75...

Страница 2: ......

Страница 3: ...5 4 Cleaning Maintenance 8 5 Troubleshooting 8 6 Error Codes 9 7 Warranty Statement 10 3 Key Product Features Reliable cooling system SECOP compressor Efficient electronic technology low energy consum...

Страница 4: ...gerator requires good ventilation especially around the vents of the refrigerator allow a gap of at least 200mm around the vents and 100mm around the rest of the unit Avoid humidity humidity inside th...

Страница 5: ...cut in value the compressor will restart automatically Battery Protection The Secop compressor requires over 10 4 Volts 12 Volt System or 23 0 Volts 24V System to operate If the voltage drops below t...

Страница 6: ...mes before automatically setting in place The display board will display the current temperature inside the unit after the target temperature is set After approximately 5 minutes the displayed tempera...

Страница 7: ...ch to Emergency override This enables the fridge to run until you reach a service centre to replace the faulty component If emergency override is enabled the compressor will run 100 of the time As thi...

Страница 8: ...ed on Press and hold ON OFF button The food inside is frozen The setting temperature is too low Thermostat override switch is enabled Bad performance in refrigeration Too much food been placed inside...

Страница 9: ...cable thickness page 5 Try on a different power source 2 Flashes Fan or compressor running issue Fan is drawing too many Amps Over 1 Amp Replace Fan The compressor is drawing too many amps Over 12 Am...

Страница 10: ...air needs to be undertaken and is covered in terms of this warranty a warranty authorisation number must be obtained prior to commencement of any work This warranty does not extend to any products acq...

Страница 11: ......

Страница 12: ...For your nearest stockist contact EvaKool T 1300 385 665 1300 EVKOOL E warranty evakool com or visit us at evakool com au...

Отзывы: