background image

09. WARRANTY CERTIFICATE 

 

 

 

 

34 

Congratulations! Thank you for purchasing an Eva Stampaggi product. 

Warranty 

 

The warranty period is two years if the product was purchased by a private customer (Legislative Decree no.  24, February 2 2002) 
and one year if it was purchased by a company or by a professional (subject to VAT). 

The tax  document referred to the product purchase gives validity to the warranty and the date on it shall be used to calculate the 
warranty period. 

 

The warranty provided shall be subject to the following terms and conditions: 

You  can  contact  the  staff  in  charge  of  the  after-sale  procedure  by  calling  0438.35469  or  by  sending  an  email  to 

[email protected] 

 

Our qualified staff will provide you with information concerning technical, installation or maintenance problems. 

Should it prove impossible to solve the issue over the phone, our staff will forward it to the Technical Support Service closest to 
you, which will guarantee assistance from a technician within 5 working days 

Any parts replaced during the warranty period shall be covered for the remaining period of the purchased product warranty. 

The manufacturer shall not pay the customer any indemnities for the inconvenience of not being able to use the product during the 
period required for repairing. 

Should it be necessary to replace the product, the manufacturer will deliver it to the retailer who will then deliver it to the end user 
following the same procedure as for the product purchase. 

This warranty is valid within Italy. Should the product be sold or installed abroad the warranty shall be recognised by the distributor 
in charge of the relevant territory. 

This warranty covers the repair or replacement of faulty parts or components or of the entire product at our sole discretion. 

 

Whenever you require assistance, you may be asked to provide: 

 

Serial number 

 

Stove model 

 

Purchase date 

 

Purchase location 

 

Warranty activation certificate filled in by an authorised Technical Assistance Centre 

 

 

 

 

 

Содержание 9.5 KW SLIM AIR-TIGHTSTOVE

Страница 1: ...INSTRUCTION MANUAL AIR TIGHT STOVES EN 9 5 KW SLIM AIR TIGHT STOVE...

Страница 2: ...Y IT IN A HORIZONTAL POSITION during transportation and installation 3 Stove installation must be carried out by qualified staff and pursuant to the regulations in force in the relevant country 4 EMPT...

Страница 3: ...2...

Страница 4: ...n the combustion chamber open the door to expel it while remaining in a position that guarantees your safety 8 It is highly important to use GOOD QUALITY CERTIFIED PELLETS The manufacturer declines an...

Страница 5: ...11 03 2 VENT PIPE 11 03 3 CHIMNEY COWL 14 03 4 DRAUGHT 15 03 5 STOVE EFFICIENCY 16 03 6 INSTALLATION 17 04 PRODUCT USE 22 04 1 ELECTRONICS WITH A 6 BUTTON DISPLAY 22 05 CLEANING AND MAINTENANCE 29 05...

Страница 6: ...nally trained for the task in question The combustion of waste especially of plastic materials damages the stove and the vent pipe Moreover it is forbidden by the law against the emission of harmful s...

Страница 7: ...nflammable materials including curtains blankets etc during normal operation may result in a fire hazard KEEP THE APPLIANCE AWAY FROM THE MATERIALS MENTIONED ABOVE Do not immerse the cable plug or any...

Страница 8: ...periods of time Whenever the hopper and the auger tube become completely empty the appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working...

Страница 9: ...8...

Страница 10: ...azione Nominal heat output Potenza termica nominale Reduced heat output Potenza termica ridotta Fuel throughput Consumo orario kg h 2 0 0 6 Necessary flue draught Requisiti minimi del tiraggio del cam...

Страница 11: ...02 PRODUCT DESCRIPTION 10 02 1 DESCRIPTION OF COMPONENTS ON OFF SWITCH REMOTE CONTROL RECEIVER SAFETY THERMOSTAT EMERGENCY SWITCH ROOM SENSOR...

Страница 12: ...of the fume evacuation system are taken into account and the following issues are addressed safety distance from combustible materials chimney flue construction smoke ducts intubated systems and chimn...

Страница 13: ...cone sealant 1 000 C Should the existing flue opening not be perfectly perpendicular to the firebox fume outlet use an elbow to connect them Inclination must never exceed 45 with respect to the vertic...

Страница 14: ...terial resistant to 400 C Optimum efficiency Traditional clay vent pipe with cavities Optimum efficiency Refractory vent pipe with insulated double chamber and external coating in lightweight concrete...

Страница 15: ...ey cowls must have useful outlet section that is at least twice that of the vent pipe be made in such a way as to prevent the penetration of rain or snow be constructed in such a way as to ensure in t...

Страница 16: ...ntal Ascending wind always results in an increased negative pressure and draught Horizontal wind results in an increased negative pressure as long as the chimney cowl was properly installed Descending...

Страница 17: ...modifying the existing chimney flue to obtain a better insulation even when it already works properly with old appliances Poor draught results in the stove not operating when hot or in smoke spillage...

Страница 18: ...ake combustion air Arrange the connection to the earthed mains The electrical system of the room where the stove is to be installed must be earthed otherwise the control board may not work properly Pl...

Страница 19: ...ONT R 1000 mm REAR WALL P 50 mm SIDE WALL 200 mm FLOORING F 0 mm FRONT R 1000 mm Besides complying with the minimum clearances set above we also recommend installing heat resistant fireproof insulatin...

Страница 20: ...LING THE PRODUCT 19 INSTALLATION EXAMPLE EXAMPLE OF INCORRECT INSTALLATION Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the exter...

Страница 21: ...inery materials or dust that can cause greenhouse gas emissions or which can easily ignite with sparks Before attempting to install the pellet stove bear in mind that all fixtures or any beams made of...

Страница 22: ...t we recommend that you charge it for at least 60 minutes the time necessary for reaching the minimum battery level that will allow the device to work properly We generally recommend that you place it...

Страница 23: ...apt the power of the blowers GENERAL SETTINGS open the general settings submenu PRELOAD available only when the stove is off There are two pre load methods available NORMAL hold the P5 key up as long...

Страница 24: ...lue 1 0 The stove resumes its operation once the room temperature drops below the set room temperature by 1 0 C Programmable thermostat The programmable thermostat function allows for the programming...

Страница 25: ...due Verify that the hopper lid and the door are closed Failure to do so could cause a malfunction of the stove and subsequent related alarms Upon initial start up ensure that in the burn pot there are...

Страница 26: ...nabled from the quick menu the stove proceeds as follows The stove enters the switching off mode passing through the intended modes if the room temperature exceeds the SET room temperature by the valu...

Страница 27: ...thermostat detected an excessive temperature exceeding the relevant threshold room sensor alarm the room sensor is connected not working properly short circuit or stopped fume sensor alarm the fume t...

Страница 28: ...04 PRODUCT USE 27 Connections...

Страница 29: ...REMAIN EMPTY TO PREVENT IT FROM BECOMING CLOGGED BY SAWDUST RESIDUES THAT HAVE SOLIDIFIED DUE TO MOISTURE 05 2 DAILY CLEANING Any cleaning operation must be performed when the stove is completely cold...

Страница 30: ...PLUG CALL TECHNICAL ASSISTANCE FAULTY FUME SENSOR CALL TECHNICAL ASSISTANCE FAULTY EXHAUST BLOWER CALL TECHNICAL ASSISTANCE FAULTY CONTROL BOARD CALL TECHNICAL ASSISTANCE POWER OUTAGE CHECK PLUG AND...

Страница 31: ...ISTANCE FUME SENSOR ALARM FAULTY FUME SENSOR CALL TECHNICAL ASSISTANCE FUME SENSOR DISCONNECTED CALL TECHNICAL ASSISTANCE HIGH FUME TEMPERATURE ALARM FAULTY FUME SENSOR CALL TECHNICAL ASSISTANCE FAULT...

Страница 32: ...1st maintenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ________...

Страница 33: ...e operate and perform maintenance on the appliance Signature of the CUSTOMER Signature of the RETAILER INSTALLER Copy of the retailer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER ____...

Страница 34: ...33...

Страница 35: ...Support Service closest to you which will guarantee assistance from a technician within 5 working days Any parts replaced during the warranty period shall be covered for the remaining period of the pu...

Страница 36: ...to chromed and or anodised and or painted metal parts or on any other treated surfaces due to rubbing or bumping with other metal parts Damage to chromed and or anodised and or painted metal parts or...

Отзывы: