06. TROUBLESHOOTING
29
PROBLEM
CAUSE
SOLUTION
FIRST START-UP
IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL START-UP AS
THE AUGER TUBE IS COMPLETELY EMPTY AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL.
DISPLAY
SWITCHED OFF
POWER OUTAGE
CHECK PLUG AND POWER SUPPLY.
FAULTY ELECTRICAL CABLE
CALL TECHNICAL ASSISTANCE.
INTERRUPTED FUSE IN CONTROL
BOARD
CALL TECHNICAL ASSISTANCE.
FAULTY CONTROL BOARD
CALL TECHNICAL ASSISTANCE.
FAULTY DISPLAY
CALL TECHNICAL ASSISTANCE.
IG
NIT
ION
F
A
IL
U
R
E A
LA
R
M
PELLETS NOT
FED TO
BURN POT
PELLETS FALL
BUT NOT LIT
STOVE
SWITCHES
OFF DURING
NORMAL
FUNCTIONIN
G
NO PELLETS
CHECK HOPPER
SAFETY THERMOSTAT
TRIGGERED
MANUALLY RESET THE THERMOSTAT LOCATED ON STOVE BACK.
AUGER TUBE BLOCKED BY
FOREIGN BODY
DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN BODY, SUCH AS NAILS, ETC.
FAULTY AUGER TUBE MOTOR
CALL TECHNICAL ASSISTANCE.
ACTIVE ALARM
SEE ALARM SECTION.
DIRTY BURN POT
CLEAN BURN POT.
TEMPERATURE TOO COLD
REPEAT SWITCHING-ON PHASE SEVERAL TIMES, EMPTYING THE BURN POT UPON EACH TIME.
DAMP PELLETS
CHECK PELLET STORAGE LOCATION.
FAULTY IGNITION PLUG
CALL TECHNICAL ASSISTANCE.
FAULTY FUME SENSOR
CALL TECHNICAL ASSISTANCE.
FAULTY EXHAUST BLOWER
CALL TECHNICAL ASSISTANCE.
FAULTY CONTROL BOARD
CALL TECHNICAL ASSISTANCE.
POWER OUTAGE
CHECK PLUG AND POWER SUPPLY.
NO PELLETS
CHECK HOPPER
AUGER TUBE BLOCKED BY
FOREIGN BODY
DISCONNECT PLUG, EMPTY HOPPER, REMOVE ANY FOREIGN BODY, SUCH AS NAILS, ETC.
POOR QUALITY PELLETS
CHANGE PELLET TYPE.
INSUFFICIENT PELLET SET VALUE
AT MINIMUM HEAT OUTPUT
CALL TECHNICAL ASSISTANCE.
ACTIVE ALARM
SEE ALARM SECTION.
POOR FLAME
ANTI-EXPLOSION DEVICE PLUG MISSING OR NOT CORRECTLY POSITIONED.
PARTIALLY CLOGGED VENT PIPE CLEAN VENT PIPE IMMEDIATELY.
COMBUSTION AIR NOT
SUFFICIENT
CLOGGED AIR INTAKE.
CLOGGED STOVE
CLEAN BURN POT AND ASH DRAWER.
FAULTY / DIRTY EXHAUST
BLOWER
GET IT CLEANED BY A SPECIALISED TECHNICIAN CALL TECHNICAL ASSISTANCE
INADEQUATE COMBUSTION AIR
SET VALUE
CALL TECHNICAL ASSISTANCE.
STAND.BY
SET ROOM TEMPERATURE REACHED / STOVE WORKS PROPERLY
DISPLAY DOES
NOT WORK
SET ROOM TEMPERATURE
REACHED
INCREASE SET ROOM TEMPERATURE SO THAT APPLIANCE GOES BACK TO "WORKING" MODE.
BURN POT
CLEANING
PERIODIC CYCLE OF BURN POT
CLEANING
STOVE WORKS PROPERLY
NEGATIVE
PRESSURE
ALARM
EXCESSIVE OR INADEQUATE
VENT PIPE LENGTH
NON-COMPLIANT VENT PIPE
CLOGGED OUTLET
CLEAN VENT PIPE / CALL AUTHORISED TECHNICIAN.
BAD WEATHER CONDITIONS
STRONG WIND.