24:Sw1,Sw2 setting
Paramter No: 24(0x18) Size:1 Byte (default=0)
Value: 00 Normal
Value: 01 Union (only switch type1 < 4 && switch type2 < 4)
IF both switches OFF - only one of them may be turned ON.
- turning sw1 ON : delayed 0.5 s, sw2 and R2 turned off first (immediately)
- turning sw2 ON - delayed 0.5s , sw1and R1 turned off first ( immediately )
The situation for DC motor control(SW1 control—right, SW2 control-left.
-main switch can turn ON and OFF only sw1
Support for Association Groups
ZW12 supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW12 Status change report,
1. ZW12 will trigger AUTO report function if the Switch status had been changed.
(ex.Switch Binary Report/Indicator Report/ Notification Report/ Device Reset Locally Notification/Sensor Binary Report)
Association group_2:basic set command on/off controlt
When the output of the ZW12 is changed, On (0xFF) or Off (0x00). The ZW12 will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command on/off controlt
When the output of the ZW12 is changed, On (0xFF) or Off (0x00). The ZW12 will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
ZW12 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:press 4x, then LED lit for 4s, within this time press 4x again – LED blinks 3 times then off to FACTORY RESET
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.