EXP120K1-HT 120KW DC Charger
1.4 Performance indicators
Indicators
Description
Observations
Input number of phases
Three-phase and four-line + PE
Input voltage range
400 VAC (+/-10%)
Input frequency
50 Hz/ 60Hz
Max input power
120KW + 20kW
Max input current
233A
System efficiency
Total charge
≥
94%
Power factor
≥
0.99
Harmonic current
≤
3% (under certain operating conditions)
Output current accuracy
≤
±0.5%
Output current accuracy
≤
±0.5%
Ripple coefficient
≤
±0.2%
Current sharing
≤
±3%
Ground detection
≤
30mA
Noise
≤
65dB (nominal input / output power, environment temperature
25°C.)
Minimum ingress protection
IP 65
Operating mode
Vertical operation
Maintenance access
Front maintenance access for system and right-side
maintenance access for power modules.
RoHS
The system meets R5 requirements in the RoHS directive
Hot plug
The system power modules are quick-connect and do not
need to restart the entire system, however the DC output must
be turned off during the entire power module exchange. After
disconnecting a power module, a break os at least 10 seconds
must be given before reconnecting it. Care should be taken
when replacing the module, inserting it slowly to avoid
mechanical damage to the pins that make the module contact
to the rest of the equipment.
AC output power
22KW
AC output voltage
400 VAC (+/- 10%)
AC output current
32A
AC connection – 1 piece
Mode-3 type 2
DC output power
120KW
DC output default voltage
600Vdc (when REG75030G power module is use )
500Vdc (when REG50040G power module is use )
DC output voltage range
150Vdc~750Vdc, tolerance ± 1Vdc (when REG75030G power
module is use)
150Vdc~550Vdc, tolerance ± 1Vdc (when REG50040G power
module is use)
DC output current
Maximum load current
≤
200A (when REG75030G power
module is use)
Maximum load current
≤
200A (when REG50040G power
module is use)
DC connection – 2 units
2 x CCS COMBO 2 or 1 x CCS COMBO 2 + 1 x CHAdeMO
DC distribution voltage drop
≤
500mV (a 25°C ambient temperature)
General
IEC 61851-1-2017
IEC 62196-1-2012
Security (LV)
IEC 60950-1
EMC
IEC 61851-21-2
EV Vision – Porto – Portugal –
www.ev-vision.com
– Support service: (+351) 229 999 230
All rights reserved. This manual may be changed without prior notice. - V 1.0 – 2019/08/10 – Pag. 8 de 25
P
o
w
e
r
d
is
tr
ib
u
ti
o
n
u
n
it
S
ta
n
d
a
rd
s
S
y
s
te
m
i
n
d
ic
a
to
rs
Содержание EXP120K1-HT
Страница 1: ......