background image

1

L3 L2

L2

L1

L1

N

N

2
3

4

5

6

7

8

9

7 - 3 pin, green

Pilot

8 - 4 pin blue

LED ring

9 - 3 pin, black

Lock motor

4 - 4 pin, green

Inputs:

4(1-2) Unused;
4(3-4) RCBO Temp. Sensor

5 - 2 pin, gray

RS485 smart charging
communication

*The port is also used for the RS485
Configuration Tool. You cannot operate
the tool and SmartGrid module together

6 - 2 pin, green

Temperature sensor

Connection group

Description

1 - 2 pin, red

2 - 2 pin, blue

3 - 3 pin, black

External relay

kWh meter

RS485 hub-satellite communication

6

High Current  

 

|

 

  Installation manual 

The High Current is connected to the EV-Box G4 series with other connectors. This one is made for 2 instead 

of 4. The wire pair is connected in the same way as the connector with 4 pins.

G4 update - BusinessLine 1.2

   

3.0

  G4-connection

Содержание High Current

Страница 1: ...02 2021 V1 0 Installation manual High Current...

Страница 2: ...ances of the specifications and can be changed without any prior notice Before placing your order always contact EV Optimizer for the latest information and specifications EV Optimizer explicitly refu...

Страница 3: ...manual High Current 1 0 High Current 4 2 0 Installation High Current 4 5 3 0 G4 connection 6 4 0 Main fuse or circuit breaker 7 5 0 Troubleshooting LED indicator 8 6 0 Correct cable specification 8 M...

Страница 4: ...rent transformers just before or right after the main fuse and put them on the 1st 2nd and 3rd phase Make sure to install them in the same way It doesn t matter in what order they are placed Step 5 De...

Страница 5: ...and plug the connector to the corresponding RS485 port in the High Current See image 1 A on page 4 Make sure that the 2 wires correspond with the connected wires of the modem in the supply station St...

Страница 6: ...t operate the tool and SmartGrid module together 6 2 pin green Temperature sensor Connection group Description 1 2 pin red 2 2 pin blue 3 3 pin black External relay kWh meter RS485 hub satellite commu...

Страница 7: ...rify if the High Current is placed in the right way If it concerns a fuse there should be 2 lights turned on If it concerns a circuit breaker there should be 1 light turned on If this is not displayed...

Страница 8: ...y station The flashing speed is equal to the power consumption If the power usage goes up the LED indicator will flash faster Continuing green The EV Optimizer is still in programming mode Put the rot...