Instruction Manual  

                                                           Temp 4/5/6 

 

5

2.5 Battery 

Replacement 

A “

LO

” annunciator in the LCD alerts you when battery power is running low. 

Replace with the same type as recommended by the manufacturer.  

 

 

 

 

Caution:

  Power off the meter when changing battery.  

 

2.6  Connecting the Temperature Sensor 

To connect a temperature probe into the meter, align the connector of probe to 
the meter’s socket and push fully until it is in position.  

 

Note: Both the Temp 4/5 use phono jacks while the Temp 6 uses a 3-pin 
connector with a locking mechanism. 

Temp 4/5 Socket 

Temp 6 Socket 

LO

.

°C 

Содержание ECOSCAN TEMP 456 PORTABLE METER

Страница 1: ...Technology Made Easy Instruction Manual Temp 4 5 6 Temperature Meter Series 68X243607 Rev 3 08 03...

Страница 2: ......

Страница 3: ...use of this meter please do not hesitate to contact the nearest Eutech Instruments Oakton Instruments Authorised Distributor Eutech Instruments Oakton Instruments will not accept any responsibility fo...

Страница 4: ...3 CALIBRATION 7 3 1 Temperature Calibration 7 3 1 1 Temperature Calibration using Offset Adjustment 7 3 1 2 Temperature Curve Selection Temp 5 Meter Only 9 4 MEASUREMENT 10 4 1 Taking Measurements 10...

Страница 5: ...um and maximum hold mode Low battery indicator Hold function freezes measured reading User calibration offset adjustment Non volatile memory backup calibration and other information remain if battery...

Страница 6: ...NTER HOLD ENTER Freezes the measured reading confirm calibration value MIN MAX MAX S UP and MIN T DOWN Momentarily displays meter s maximum and minimum temperature enter maximum or minimum hold mode s...

Страница 7: ...edges of meter until it is completely out of boot Ensure that the connector of temperature sensor is not connected 2 To insert meter into rubber boot slide in from the top of meter before pushing the...

Страница 8: ...tery compartment is found at the back of instrument To open the battery compartment push in the direction of arrow and lift up the cover Note the polarity of battery before inserting into position Aft...

Страница 9: ...manufacturer Caution Power off the meter when changing battery 2 6 Connecting the Temperature Sensor To connect a temperature probe into the meter align the connector of probe to the meter s socket a...

Страница 10: ...r All the LCD segments display momentarily as the meter performs a self diagnostic test per shown in section 2 2 The LCD then switches into measurement mode 2 The LCD displays oPEn if the temperature...

Страница 11: ...temperature probe to the meter Press ON OFF key to power up the meter and wait for meter to enter measurement mode 2 Dip the probe in a constant temperature bath or in liquid whose temperature can be...

Страница 12: ...6 Press ENTER key to confirm calibration 7 The LCD displays CO momentarily and the meter then reverts to measurement mode See figure below From measurement mode Press down CAL key for 5 seconds before...

Страница 13: ...asurement mode Press CAL key for 5 seconds to enter calibration mode The LCD shows CA and the reading flashes 3 Press o C o F key to enter curve selection mode Press the o C o F key again to scroll th...

Страница 14: ...4 2 Displaying Maximum and Minimum Readings The EcoScan Temp meter can momentarily display the maximum and minimum temperature measured since you switched the meter on Simply press MAX S or MIN T key...

Страница 15: ...nce entering the Maximum or Minimum Hold mode 1 Power on the meter The meter automatically enters Temperature mode Use o C o F key to switch between Celsius and Fahrenheit reading if desired 2 Press H...

Страница 16: ...g MIN key 3 The meter goes through the power up sequence before coming to measurement mode 4 The LO indicator will blink for every 2 seconds indicating that the auto power off feature is disabled NOTE...

Страница 17: ...ution No display when turned on a Batteries not in place a Insert batteries b Re insert batteries in correct polarity oPEn display on LCD a Probe not connected a Make sure probe is firmly connected Ur...

Страница 18: ...99 9 o C 391 9 o F Accuracy 0 2 o C 0 4 o F 0 2 o C 0 4 o F 99 9 to 199 9 o C 99 9 to 391 9 o F 2 o C 4 o F range 99 9 o C 99 9 o F and range 199 9 o C 391 9 o F Hold Function HO Auto Power Off Select...

Страница 19: ...00 35626 00 General Purpose Probe 93824 00 Temp 5 Meter with probe EC TEMP5 01 35626 10 100K Thermistor Temperature probe EC TEM5TEM01P 35626 50 Temp 6 Meter with probe EC TEMP6 01 Temp 6 Meter only...

Страница 20: ...r misuse within the designated period please return freight pre paid and correction will be made without charge Eutech Instruments Oakton Instruments will determine if the product problem is due to de...

Страница 21: ...he reason the items are to be returned For your protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Eutech Instruments Oakton Instrument...

Страница 22: ...NOTES...

Страница 23: ...NOTES...

Страница 24: ...ruments P O Box 5136 Vernon Hills IL60061 USA Tel in U S 888 462 5866 Tel outside U S 1 847 549 7600 Fax 1 847 247 2984 E mail info 4oakton com www 4oakton com Eutech Instruments Pte Ltd Blk 55 Ayer R...

Отзывы: