5. LED Indicators 

On the front panel of UVE7312-MSBC, there are 5 LED indicators as the following 
 

POWER

:

  “

Green On

” indicates power is on and normal. 

 

LAN1

:

 

Green On

” indicates Ethernet LAN1 port is in connection. 

 

 

Flashing

” indicates Ethernet LAN1 data activities. 

 

LAN2

:

 

Green On

” indicates Ethernet LAN2 port is in connection. 

 

 

Flashing

” indicates Ethernet LAN2 data activities. 

 

BNC

:

 

Green On

” indicates VDSL2 Cable is in connection. 

 

Flashing

” indicates VDSL2 Cable is in line handshaking. 

 

M/S

:

 

Green On

” indicates UVE7312-MSBC is set as Slave ( VTU-R ) mode. 

 

OFF

” indicates UVE7312-MSBC is set as Master ( VTU-C ) mode. 

 

 
 

6.  Dip Switches Settings 

 

 

 

Pin 1 

Pin 2 

Pin 3 

Pin 4 

 

VTU-C/R Mode Rate 

Limit SNR 

OFF 

VTU-C 

Interleaved 

50 / 20 Mbps

9dB 

ON 

VTU-R Fast 

Full 

Rate 6dB 

 
 

 

 

 

Pin 1

:  

VTU-C/R Switch

 

 
VTU-C:

   

UVE7312-MSBC will act as at the Central Office (CO) side.

 

 
VTU-R:

   

UVE7312-MSBC will act as at the Customer Premise Equipment (CPE) or Remote side. 

 
 
 
 
 
 

Содержание UVE7312-MSBC

Страница 1: ...1 Ethernet over VDSL2 BNC Cable Converter UVE7312 MSBC User Manual Ver 1 02 Copyright EUSSO Technologies Inc All rights reserve ...

Страница 2: ...1 Table of Content 1 Introductions 2 2 Application Notes 2 3 Features 3 4 Packing Contents 3 5 LED Indicators 4 6 Dip Switches Settings 4 7 Data Rates Distances 5 ...

Страница 3: ...ta rate or a fixed SNR margin for different coaxial cable ranging With plug and play features and minimum installation time each UVE7312 MSBC can be configured into either CO for central side or RT for remote side by dip switch setting The UVE7312 MSBC conforms to the ITU T G 993 1 and G 993 2 to meet VDSL VDSL2 and SG15Q4 DMT for network requirements A pair of UVE7312 MSBC offers a cost effective...

Страница 4: ...y impulse noise with a duration less than 250 us Interleaved mode has a maximum end to end latency of 10 ms Interleaved mode is the default mode Selectable fixed data rate and fixed SNR margin z User may select fixed SNR margin 9 dB or fixed target data rate z When fixed SNR margin is selected the systems will maintain the SNR margin at 9 dB across all available loop length z When fixed target dat...

Страница 5: ...2 data activities BNC Green On indicates VDSL2 Cable is in connection Flashing indicates VDSL2 Cable is in line handshaking M S Green On indicates UVE7312 MSBC is set as Slave VTU R mode OFF indicates UVE7312 MSBC is set as Master VTU C mode 6 Dip Switches Settings Pin 1 Pin 2 Pin 3 Pin 4 VTU C R Mode Rate Limit SNR OFF VTU C Interleaved 50 20 Mbps 9dB ON VTU R Fast Full Rate 6dB Pin 1 VTU C R Swi...

Страница 6: ...ides up to 100Mbps 60Mbps line rate in short line Pin 4 Signal to Noise Ratio SNR 9dB Higher SNR margin 9dB will result in less error with more stable VDSL2 link 6dB Original and Normal channel noise protection with 6 dB SNR 7 Data Rates Distances Performance in 5C2V Cable at 6dB with full rate Down Stream Data Rate Mbps Up Stream Data Rate Mbps Distance feet 107 60 500 103 58 1000 100 56 1250 98 ...

Отзывы: