STORAGE

If the wheelchair is stored for a longer period without being used ( one month or more) it should be 
stored in a clean, moisture-free, room- temperature space. The batteries should be charged approx 
once a month to prevent them from falling to the critical level where the charger no longer starts the 
charging. 

CHARGING THE BATTERIES

To obtain the batteries full performance for as long time as possible it is important that they are being 
charged regularly. Preferably as soon as the wheelchair is parked.The batteries benefits from constant 
charge. The batteries should be charged at least every night if the chair has been used during the day. 
Don´t cancel the charging before it is completed. The charging can be done indoors in your home. Dur-
ing storage the batteries should be charged approx once a month to prevent them from falling to the 
critical level where the charger no longer starts the charging. 

 NOTE! 

 

If the batteries are damaged or leaks, all contact should be avoided to prevent burns. Seek 

immediate contact with the authorized dealer! Used batteries should be sent for recycling.
Connect the charger plug to the joystick on the chair. It is located on the front of the joystick. See pic-
ture. Connect the  charger´s wall socket.Check using the charger lights that the charging has started. 
Information regarding the charger is attached together with the charger. Disconnect the charger when 
the chair is to be used. 

ADJUSTING THE MANEUVER BOX 

The maneuver box can be adjusted in 
depth (1) and sideways (2).  

Adjust all positions with 
an allen key no 5 mm to desired position. 

The maneuver box can be moved both to 
the outside and inside of the armrest. 

1

2

3

4

Содержание Euroflex Reflex

Страница 1: ...1 English User Manual Reflex part no BRU E 30 401 Rev 201502 5...

Страница 2: ...onic Dynamic 9 Control box electronic PG 10 Storage 11 Adjustment of control box 11 Charging of batteries 11 Checklist service recond 12 Service manual 13 14 Troubleshooting 15 17 Technical informatio...

Страница 3: ...tention to screws or parts that become loose or fit loosely on the wheelchair as this may af fect safety contact the service organisation Service and maintenance should be carried out by trained perso...

Страница 4: ...cturer for help and questions Be careful always tighten knobs or screws after performed seat adjustments STORAGE The chair should be stored in a dry roomtempered environment Avoid exposing the chair f...

Страница 5: ...turer s name 8 Barcode Eurovema AB Baldersv gen 38 SE 332 35 Gislaved 46 0 371 39 01 00 www eurovema se info eurovema se Reflex XXX Part no xxx xx x S no xxxxxxxxxx Date xxxxxx 0X XXXXXXXXXXXXXX XX XX...

Страница 6: ...4 755001 7100 Front wheel 5 SW 01478 Front frame 6 SW 01468 Actuator attachment 7 7YA17 12 Battery 8 755001 7000 Drive wheel 9 7DX2 PMA70 Power module 10 SW 01506 Anti tipping support 11 669201 1700 S...

Страница 7: ...so be used as a mains switch During storage the fuse should be in the triggered position The fuse must be pressed in during charging NOTE NOTE When charging the batteries for maintenance the fuse must...

Страница 8: ...chair and the error message will disappear RISK OF INJURY NOTE Make sure the wheelchair is on level ground when the brakes are disconnected Otherwise the wheelchair can roll away without control TRAN...

Страница 9: ...n r en bekv m styrfart F r att s nka hastigheten tryck p knappen med en sk ldpadda 2 f r att ka hastigheten tryck p knappen med en hare 3 F r att finjustera hastigheten h ll in knapp 2 alt 3 till nska...

Страница 10: ...ontrolled using the control box The joystick is used to drive the wheelchair in the desired direction The electronics can be programmed to suit the individual s wishes but usually the original program...

Страница 11: ...doors in your home Dur ing storage the batteries should be charged approx once a month to prevent them from falling to the critical level where the charger no longer starts the charging NOTE If the ba...

Страница 12: ...achment Retightening Wiring wear 3 CHASSIS Weldings Screw joints 4 DRIVING WHEEL Function roll Wheel bearings wheel conveyors Attachment retightening 5 STEERING WHEEL Function roll pivoting Wheel bear...

Страница 13: ...on the shoulder Refit the four screws MOUNTING DEMOUNTING STEERING WHEEL Loosen the screw with an allen key no 5 mm spanner no 13 mm Remove the steering wheel mount the new steering wheel and tighten...

Страница 14: ...sconnect the main power 2b Unscrew the nobs screws from the coat with an allen key no 5 3b Loosen the straps and cables from the poles Change both batteries mount the cables and tighten the straps aro...

Страница 15: ...terval of 2 seconds Number of 1 12 flashes shows the type of error that occurred About the table Errors who affects the driving safety will automatically stop the chair while less risky errors will be...

Страница 16: ...he error is a damaged bus cable between the maneuver box and the electronics unit 10 Flashes CANH error The CANH wire in the DX bus is used partly for communication between electronics modules partly...

Страница 17: ...t Parking brake error M2 7 SHARK drive unit error 8 SHARK Power module error 9 SHARK connection error 10 Unknown error 11 Incompatible controller Error message Each error on the DX will be indicated b...

Страница 18: ...nter The batteries will not recieve charging The circuit breaker has been tripped Control the circuit breaker see manual The batteries are discharged Contact the technical aids center The charger is b...

Страница 19: ...19 English...

Страница 20: ...20 English part no BRU E 30 401 Rev 201502 5...

Отзывы: