2.0 SAFETY 

  Please read the following safety notice carefully before operating the pump.

 

 
2.1  General Notices 

-  Understand fully this installation and operating manual before operation. 

-

  Any other person except authorized operator should not operate the vacuum pump 

-

  When the pump is not properly working, it should be stopped immediately.  

-

  Eurovacuum shall have no liability for any accident and failure arising from no compliance with 

instructions in this manual. 

 
2.2  Warning labels and its explanation 

  Following warning labels are shown and attached on EVDR series pumps 

  2.2.1 No oil: 

No oil should be used in this pump and the intake of oil and oil mist must be prevented 

  2.2.2 Read operating instruction manual: 

Read and understand operator’s manual before using this machine 

2.2.3 Vane inspection 
    

   Inspect the size of the vanes after 3.000 hours of running 

 

  2.2.4  Location of the labels 

   

The labels shall be shown on the top of sound shield of the pump. 

 

2.3  Risks and warnings 
  2.3.1 Risk of burns 

     

During operation the surface of the pump may reach temperatures of more than 70°C. 

 

Avoid contact with the pump during and after directly after operation. 

  2.3.2 Risk of damage to hearing 

If people are present near to the pump over extended periods then there is a risk hearing 

damage. 

 

Ear protection must be used. 

 

Do not lubricate the compression chamber of the pump with oil or grease 

  2.3.3 Damage to the pump 

 

Do not lubricate the compression chamber of the pump with oil or grease 

 

Avoid more than 10 on/off switches of the pump per hour 

 

Содержание EVDR Series

Страница 1: ...Eurovacuum Installations and Operating manual EVDR Series Vacuum pumps Models EVDR V010 till V040 Dry Rotary Vane Vacuum Pump...

Страница 2: ...cription 1 2 Unpacking and Storage 1 3 Location 1 4 Power Requirements 1 5 Vacuum Connections 2 0 SAFETY 2 1 General Notices 2 2 Warning Label and explanation 2 3 Risks and warnings 3 0 OPERATION 3 1...

Страница 3: ...ed with plastic caps to prevent dirt and other foreign substances from entering the pump Leave the cap in place until you are ready to pipe the pump to your equipment The pump should be stored in a dr...

Страница 4: ...in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction line adjacent to the pump suction flange The built i...

Страница 5: ...ted 2 2 2 Read operating instruction manual Read and understand operator s manual before using this machine 2 2 3 Vane inspection Inspect the size of the vanes after 3 000 hours of running 2 2 4 Locat...

Страница 6: ...wear ear protectors If noise below the designed dBA is required an external sound enclosure can be added to the system provided adequate ventilation is provided The ambient and suction air temperatur...

Страница 7: ...motor Remedy Call service agent for service or exchange program 5 2 Problem Pump does not reach its usual vacuum level 5 2 1 Possible Cause Filters are clogged with debris Remedy Clean the filters or...

Страница 8: ...nal speed at 50 60Hz rpm 1420 1700 1420 1700 Noise level with exhaust silencer 50Hz dB A 60 3 61 3 Cooling medium air air Weight approx kg 15 22 Admissible ambient temperature C 0 to 40 0 to 40 Connec...

Страница 9: ...Eurovacuum Head office Tel 31 0 854890993 Einsteinstraat 58 info eurovacuum eu 2811EP Reeuwijk http www eurovacuum eu The Netherlands...

Отзывы: