The motor must be connected according to the electrical codes through a fused switch in order to      
protect the motor against electrical or mechanical overload conditions. The overload of the motor 

starter must be set at a level equal to the full load motor current listed on the motor nameplate.

 

 

Check the rotation connection before starting the pump, the correct direction of rotation is marked by 
an arrow on the pump casing. 
 
Avoid more than 10 switches per hour. 
 

After electrical connections have been made, the rotation of the motor must be checked. If 
backward, reverse any two leads of the three at the power connection.

 

 

1.5  Vacuum Connections 
 

Use a pipe size that is at least the size of the pump inlet connections. Smaller lines result in a reduced    
pump capacity. 

 

    Pumps operating in parallel on a common main line should have a manual or automatic operated        

shut-off valve or positive action check valve, installed in the suction line adjacent to the pump 
suction flange. The built-in anti-suck back valve should not be used as a shut-off valve for the 
vacuum system. Remove the plastic protective cap from the inlet port prior to connection of pump to 
the system. 

  

    Should process gas contain dust or other foreign particles, a suitable in line (inlet) filter should be 

connected to the inlet port. Consult Eurovacuum for recommendations. 

    The vacuum piping should be designed to ensure that no liquids such a condensate or liquid carried    

over from the process can reach the pump. If this possibility exists, a knock-out liquid separator 
should be installed. Consult Eurovacuum for recommendations. 

 

 The following thread sizes are standard on the pumps 

 

 

Pump Model

 

Inlet Size

 

 

 

EVDR-V010 & V016

 

G 1/2” 

 

 

EVDR-V025 & V040

 

G 3/4” 

 

 
 
 
 
 

Star Connection 

High Voltage 

L1 

L2 

L3 

W2 

U2 

V2 

U1 

V1 

W1 

Содержание EVDR Series

Страница 1: ...Eurovacuum Installations and Operating manual EVDR Series Vacuum pumps Models EVDR V010 till V040 Dry Rotary Vane Vacuum Pump...

Страница 2: ...cription 1 2 Unpacking and Storage 1 3 Location 1 4 Power Requirements 1 5 Vacuum Connections 2 0 SAFETY 2 1 General Notices 2 2 Warning Label and explanation 2 3 Risks and warnings 3 0 OPERATION 3 1...

Страница 3: ...ed with plastic caps to prevent dirt and other foreign substances from entering the pump Leave the cap in place until you are ready to pipe the pump to your equipment The pump should be stored in a dr...

Страница 4: ...in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction line adjacent to the pump suction flange The built i...

Страница 5: ...ted 2 2 2 Read operating instruction manual Read and understand operator s manual before using this machine 2 2 3 Vane inspection Inspect the size of the vanes after 3 000 hours of running 2 2 4 Locat...

Страница 6: ...wear ear protectors If noise below the designed dBA is required an external sound enclosure can be added to the system provided adequate ventilation is provided The ambient and suction air temperatur...

Страница 7: ...motor Remedy Call service agent for service or exchange program 5 2 Problem Pump does not reach its usual vacuum level 5 2 1 Possible Cause Filters are clogged with debris Remedy Clean the filters or...

Страница 8: ...nal speed at 50 60Hz rpm 1420 1700 1420 1700 Noise level with exhaust silencer 50Hz dB A 60 3 61 3 Cooling medium air air Weight approx kg 15 22 Admissible ambient temperature C 0 to 40 0 to 40 Connec...

Страница 9: ...Eurovacuum Head office Tel 31 0 854890993 Einsteinstraat 58 info eurovacuum eu 2811EP Reeuwijk http www eurovacuum eu The Netherlands...

Отзывы: